6.4.2 PMP Status Codes
The PMP status code is displayed in a series of hexadecimal characters representing the
status of different alarm conditions. The value '1' indicates the associated condition is
active. All unused bits are set to zero.
To determine the status, the hexadecimal number must be converted to binary notation. It
is recommended to use a scientific calculator that supports binary notation (i.e., Windows
on-screen calculator). Set the mode for Hex and enter the status code. Change the mode
to binary and match active bits (1) to the PMP Status Codes table.
For example, if 'Tx Low Power' (bit 0) and 'PLL Error' (bit 6) were active, the status code
value would be Hex '41' (binary 1000001).
Table 37
:
Diag. - PMP Status Code Bits
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 9 8 7 6 5 4 3 2 1 0
Table 38
:
Diag. - PMP Status Codes
Bit Description
0
Tx Low Power
1 Radio
over-temperature
4, 5, 6
PLL Errors
8 Firmware
Error
16
No Ethernet packets received by the wireless MAC
17, 18, 19, 20,
21, 22, 23, 24,
25, 26, 27, 28
MAC Internal Errors