6.4 Status
Codes
6.4.1 PTP Status Codes
The PTP status code is displayed in a series of decimal characters representing the status
of six different alarm conditions. The value '1' indicates the associated condition is active.
All unused bits are set to zero.
To determine the status, the decimal number must be converted to binary notation. It is
recommended to use a scientific calculator that supports binary notation (i.e., Windows
on-screen calculator). Set the mode for decimal and enter the status code. Change the
mode to binary and match active bits (1) to the following table.
For example, if 'Tx Power' (1) and ' PHY lock error' (1 0000) were active, the status code
value would be 33 (binary 100001 (leading zeros are not displayed).
Table 36
:
Diag. - PTP Status Codes
Error Type
Error #
Decimal*
Error #
(binary)
Description
Tx Power
1
1 Power output is less than 10 dBm.
RF High
Temp.
Warning
2
10 The transceiver internal temperature rose above
185F / 85C. The transceiver will shut down for 30
seconds to allow cooling.
RF PLL Lock
Error
16
1 0000 The PLL (Phase Locked Loop) section within the
AN-80i experienced an error. Reset the AN-80i.
PHY lock
error
32
10 0000 The PLL (Phase Locked Loop) section within the
AN-80i experienced an error. Reset the AN-80i.
80 MHz PLL
lock error
64
100 0000 The PLL (Phase Locked Loop) section within the
AN-80i experienced an error. Reset the AN-80i.
Firmware
Configuration
Error
128
1000 0000 Error detected in the AN-80i configuration file.
*Displayed decimal value if this is the only active error condition.