configuration process to try to resolve the problem.
203-Another upgrade in progress!
The system is already in upgrade mode, in the event
the operator inadvertently invoked multiple
simultaneous upgrades.
204-Invalid upgrade parameters!
The parameter entered is in error. If this message
appears, check for typing errors.
205-Upgrade
failed!
The software upgrade process completed
unsuccessfully.
206-Password changed unsuccessfully!
The new password entered into the system was not
successful. In this case, repeat the process.
207-Timeout on reading data packet!
The system has timeout looking for packets from the
host computer or server. Check for obvious problems
such as disconnected or faulty cable. A mis-
configured TPTP server will also cause this error
209-TFTP error received!
The Trivial File Transfer Protocol (TFTP) routine used
to download the software to the AN-50 terminal during
the Upgrade process failed. Likely cause is
disconnected or faulty cable.
210-Error: TFTP unknown message!
The TFTP client received an unknown message. In
this case, repeat the upgrade process.
211-Error: while writing flash!
While writing the new software into AN-50 terminal
flash memory an unexpected error occurred. Try to
repeat the process and if the error persist contact
your local Redline representative.
212-Error
firmware
configuration!
An unexpected error occurred while writing the
onboard firmware configuration. Try to repeat the
process.
213-Firmware programming failed!
The firmware programming failed.
214-Error
while
loading
version
control!
Software version control data was not loaded
successfully.
215-Log buffer full!
The log buffer overflowed.
216-Invalid Options Key!
User entered an invalid Product Options key.
217- PLL unlocked!
One or more RF synthesizers unlocked. The unit
stopped RF transmissions and attempted to
reprogram the synthesizers. If this message repeats
or if the RF link is not back on, try to reset the
terminal. If the problem persists, contact customer
support.
218
-
Outdoor unit over temperature!
The T-58 Transceiver's internal temperature rose
above 185F / 85C. The transceiver will shut down for
30 seconds to allow cooling.
219-Excessive DC loss on IF cable!
The DC voltage at the transceiver (carried by the IF
cable from the AN-50 terminal) is lower than the
required 24VDC. Check the IF cable and connectors.
220-Outdoor unit power supply fault!
Indicates a fault in the transceiver's power supply.
This error could be due to a problem with the internal
power supply, or with the power source from the AN-
50 terminal. If the 'Excessive DC loss on IF cable'
error is also indicated, check the IF cable and
connectors. If not, the T-58 Transceiver will require
servicing.
Page 45 of 76
Summary of Contents for AN-50
Page 1: ...AN 50 System User Manual AN 50 System User Manual PTP PMP Manual 70 00001 01R00 Release 2 01 ...
Page 2: ...AN 50 System User Manual Page 2 of 76 Redline Communications solving the first mile challenge ...
Page 73: ...AN 50 System User Manual ...
Page 74: ......
Page 75: ......
Page 76: ...302 Town Centre Blvd Markham Ontario Canada L3R 08E www redlinecommunications com ...