27
See Figure 18
2. Mount the pulley (1) on the drive shaft with the supplied taper-lock bus.
3. Mount the extractor (2) and tighten it with the supplied M8x20.3 bolts.
4. Place the strips (4) on the Verti-Top aligned with the tapped holes.
5. Open the vacuum box (5).
6. Place the vacuum box (5) on top of the strips (4) and bolt it loosely with the supplied
M8x20 bolts (6) and rings (7).
7. Mount the V-belt (8) and align it.
8. Tighten the V-belt (8) by moving vacuum box 5 until you reach the correct tension.
9. Check the tension of the V-belt by pulling on point A with a tension of 4.5 kg (9.9lbs).
The stretch should be 2 mm (0.08”).
10. Tighten the M8x20 bolts (6) in the vacuum box.
11. Mount the hose (9) between the vacuum box (5) and the extractor (2) using the hose
clips (10).
12. Check whether there are components that run out of true and whether all
components are mounted well and tight.
13. Mount the safety caps (11 and 12).
14. Hang the dust bag (13) on the hooks (14) and fixed to the suction mouth (15).
15. Tighten the taut band (16).
16. Close the vacuum box (5).
17.1.1
SETTING THE SUCTION FORCE
1
2
3
Figure 19
The suction force can be adjusted on the vacuum-unit.
The procedure is as follows
(see Figure 19)
:
Make sure that the Verti-Top is blocked well and cannot move on its
own accord!
1. Loosen the wing nut (1) and adjust the stellar knob (2).
Adjust both sides of the machine in a parallel manner. For this purpose, use
the indication sticker (3).
Downwards = Less suction force
Upwards = More suction force
Standard setting = 2
2. Tighten the wing nut (1) when you have reached the desired setting.