Safety 

     

 

 

The  wiring  diagrams  and  installation  instructions  are  given  as  a  guide  only  and 
compliance to appropriate standards is the responsibility of the installer. Relevant 
standards are listed below: 

 

AS/NZS 3000:2018 

Wiring rules 

AS/NZS 5033:2021 (and 1&2)  Installation and safety requirements for photovoltaic (PV) arrays 

AS/NZS 4509.2:2012 

Stand-alone power systems-Design 

AS/NZS 1170.2:2011 

Structural design actions-Wind actions 

AS/NZS1768:2007 

Lightning protection 

AS/NZS 3008.1.1:2017 

Electrical installations – Selection of cables 

AS/NZS 5139:2019 

Electrical  installations-Safety  of  battery  systems  for  use  with  power 
conversion equipment 

 

The HoneyBadger must only be installed by suitably qualified personnel who have read 

and are familiar with its operation and hazards. 

 

The  battery  provided  with  this  system  must  be  charged  only  by  the  Victron 

inverter and MPPT. Do not attempt to charge the batteries with any other charger 

device or connect any devices directly to the DC battery bus unless approved by 

RedEarth. 

 

In the event of a fire evacuate the area and call emergency services. A dry agent 

fire extinguisher should be readily available and used. DO NOT use water.  
Note:  MSDS  document  is  provided  with  the  system  and  can  be  found  at 

www.redearth.energy

 

 

Do  not  use  a  damaged  battery.  Batteries  should  only  be  disposed  of  at  an 

appropriate recycling centre. Please contact RedEarth for advice.  

 

A battery can present a risk of electrical shock and high short-circuit current. The 

following precautions should be observed when working on batteries: 

 

Disconnect charging source prior to connecting or disconnecting battery 

terminals. 

 

In our efforts towards constant product enhancement, this document is subject 

to change at any time. Please visit 

http://www.redearth.energy

 

and download the 

appropriate and latest version manual. 

Symbol 

Explanation 

 

Refer to the operating instructions 

 

Indicates additional information, emphasized contents or tips that may be helpful. 

 

Caution, risk of electric shock. 

 

Caution, risk of danger. 

 

Do not touch live parts until 10 minutes after disconnection from the power 

sources. 

Summary of Contents for HoneyBadger

Page 1: ...HoneyBadger Home Battery System Off Grid Victron with Troppo 4841 Lithium Batteries Installation Manual...

Page 2: ...eries with any other charger device or connect any devices directly to the DC battery bus unless approved by RedEarth In the event of a fire evacuate the area and call emergency services A dry agent f...

Page 3: ...HoneyBadger installation 11 Step 1 Transporting 11 Step 2 Positioning 12 Step 3 Solar Installation 12 Step 4 Electrical connections 14 4 1 Solar 15 4 2 AC Connections 15 4 3 Battery 17 4 4 Remote Moni...

Page 4: ...y via an external switch board with an earth stake and MEN link there are dedicated terminals inside the unit to connect to PV solar panels with one array per MPPT maximum 250VDC per string with two M...

Page 5: ...no windows doors etc are allowed According to AS NZS 5139 Note if the system is 300mm off the wall then this does not apply The HoneyBadger is rated for outside installation It should be installed in...

Page 6: ...T s and all of the electrical switch gear The bottom section is pre wired for up to eight of RedEarth s 4 1kWh Troppo batteries Each section has a key lockable door Note that the keys are not the same...

Page 7: ...te 18 07 2022 Face plate Behind the face plate are the connection points required for installing the system This area should only be accessed by qualified personnel The faceplate is held in place by f...

Page 8: ...the 2 wire auto start for a generator A Victron smart charger is also included in the parts kit This is to provide a continuous trickle charge to the starter battery of the generator It can be plugged...

Page 9: ...sound that can be muted by pressing Silence Contact your installer More information on the Earth Fault device is available at the following link www aerl com au wp content uploads 2020 10 EarthGuard 3...

Page 10: ...to allow easy connection of additional batteries in the future Parts kit HoneyBadger The HoneyBadger is supplied with documentation and a parts kit box to complete the installation Documentation late...

Page 11: ...confirm remote operation 8 Customer Handover including helping with access to RedEarth EMU app Step 1 Transporting The HoneyBadger system is supplied on a pallet as shown at right It is fully set up f...

Page 12: ...ose of the tape is to avoid paint chipping during transportation This can now be removed Step 3 Solar Installation The PV Array should be designed and installed in accordance with AS NZS 5033 and the...

Page 13: ...reverse battery polarity however this is not an issue as it is pre wired by RedEarth Victron have the following comments about connecting the PV polarity in reverse which is in the installers hands Fu...

Page 14: ...h connector 4mm2 PV cable can be used before the second branch connector as the current is below the 30A rating with 4mm2 cable Step 4 Electrical connections To access the cable connection points remo...

Page 15: ...holes on either the left or right of the system then sealed appropriately with 25mm or 32mm glands and conduit The Appendix A contains a SLD for the system wiring The AC wiring can be more easily com...

Page 16: ...ger The following specifications must also be met for a guaranteed compatibility with the inverter Generator waveform THD 10 Generator Vrms range 180 264Vac Generator voltage crest factor Vpeak Vrms 1...

Page 17: ...essing the button on the side of the terminal and pull it straight up NOTE When installing the battery cable simply push it onto the terminal until you hear a click 2 Remove the bolt that holds the ea...

Page 18: ...tenna outside To access the antenna remove the four screws that hold the vent cover on the right side of the unit Unplug the antenna from the RedPi Lite monitoring device pass it through the 16mm2 gla...

Page 19: ...on each battery will come on 2 Switch on the BATTERY SYSTEM D C ISOLATOR the Quattro Inverter and CCGX display will start note the small black switch on the front of the Inverter itself needs to be i...

Page 20: ...connecting a laptop to the HoneyBadger a MK3 device is required This is not supplied with the HoneyBadger but is available separately The VE Config program can be downloaded from Victron s web page h...

Page 21: ...included antenna needs to be placed in a suitable location outside the system as described in Step 4 4 If no mobile coverage is available but internet is available e g via SkyMuster or Starlink servi...

Page 22: ...et the most from your investment in your HoneyBadger It will also register your email You will then immediately be sent an email that allows you to log into the EMU app Download RedEarth s EMU app Cli...

Page 23: ...ptop computer To access the VRM portal email or call RedEarth tech support with the serial number of your Honey Badger it can be found on the inside of the top door and looks like this HB xxxxxxx You...

Page 24: ...5 The battery and DC terminal connections are tight Check during installation 6 Insert the supplied blanking plugs into the unused holes in the side of the unit and reinstall the side vents Handover...

Page 25: ...edEarth You can receive regular relevant communications from RedEarth Other benefits include Access to RedEarth s PPP Private Power Plant and the stream of financial benefits available to the customer...

Page 26: ...HoneyBadger Installation Manual HoneyBadger Install Version 2 Page 26 of 32 Issue Date 18 07 2022 Appendix A Single Line Diagrams...

Page 27: ...HoneyBadger Installation Manual HoneyBadger Install Version 2 Page 27 of 32 Issue Date 18 07 2022...

Page 28: ...chnical Specifications Victron Quattro inverter charger Selected specifications The HoneyBadger uses the 48 10 000 100 as the standard inverter The 48 5000 70 100 100 inverter is available as an optio...

Page 29: ...llation Manual HoneyBadger Install Version 2 Page 29 of 32 Issue Date 18 07 2022 Troppo 4841 Battery specifications Short circuit Current ISC 1x 0 4 kA 2x 0 8 kA 3x 1 2 kA 4x 1 6 kA 5x 2 0 kA 6x 2 4 k...

Page 30: ...HoneyBadger Installation Manual HoneyBadger Install Version 2 Page 30 of 32 Issue Date 18 07 2022...

Page 31: ...Installation Manual HoneyBadger Install Version 2 Page 31 of 32 Issue Date 18 07 2022 RedEarth Energy Storage Ltd 15 Fienta Place Darra Brisbane QLD 4076 Australia Tel 1800 733 637 Email support rede...

Page 32: ...HoneyBadger Installation Manual HoneyBadger Install Version 2 Page 32 of 32 Issue Date 18 07 2022 Web www redearth energy...

Reviews: