Redback® A 4480B
8 In to 8 Out Audio Switcher
Fig 5.1D
5.1.5 Cascading the paging consoles with 8 zone wallplates and a preset plate.
The situation may arise where all 8 zone wall plates, a preset wallplate and two or more paging consoles are required.
In this case the configuration shown in Fig 5.1D may be used. In this figure six paging consoles have been connected to
ports 1-3. This is the maximum number of paging consoles allowed in this configuration. The A 4476 preset wallplate may
be connected to any of the paging console inputs or any zone wallplate input. Note that each paging console must be
assigned an ID number before operation (see 5.1.2 DIP switch 4). In cascade operation, each A 4481 paging console must
be powered by individual 24V DC power supplies (Altronics part: M 8968C).
Peripheral Connections
5.1.6 Multi-zone paging
Paging is achieved by pressing the numbered button of the zone required. The button will illuminate. Hold down the page
switch and speak into the microphone. Note: a zone with a fast flashing LED has general paging blocked. To page to
multiple zones, press the buttons for the desired zones. Multiple buttons will illuminate. Hold down the page switch and
speak into the microphone.
5.1.7 Zone lock out
General paging can be blocked to any zones either at the A 4480B main unit or via the paging consoles. To block paging
to a zone from the A 4481, hold down the desired zone button until a message on the LCD indicates the zone is blocked
out. Release the button to resume. To unlock the zone, repeat the procedure.
Output levels
Voice Chime Alert
Over
& Evac
24VDC In
(4A M205)
Lift/Chassis
ZONE PLATES OR PRESET PLATE
Keyboard
INPUTS
SW2
SW1
8
7
6
5
4
3
2
1
Vox
Level
Volume
Priority Input
L
R
Vox
Level
Trigger
To Paging Consoles/Preset Plate
3
4
1 2 3 4
ALERT - EVACUATION MODULE
1 2 3 4
L
R
SW3
EV
CO
M
CH1/ C
AN
CH2
AL
2 - Hot
1 - Shield
2 - Hot
3 - Cold
2
1
3
SW3 Input 1 & 2 XLR
Phantom Power Settings
SW
ON OFF
(1) Input 1
ON OFF
(2) Input 2 ON OFF
Triggers
OUTPUT
S
8
7
6
5
4
3
2
1
EMERGENCY INPUT
DC Fuse
Earth Lift
+
-
24VDC In
Power Fail
+
_
Manufactured in Australia By
Altronic Distributors Pty. Ltd.
www.redbackaudio.com.au
BCD & DIP SWITCH SETTINGS
DIP SWITCH
CHIME CONTACT
4
5
6
7
CH2
CH1/CANCEL
OFF OFF OFF OFF
Pre Announce
Ding Dong
ON OFF OFF OFF
Pre Announce Repeating Bong
OFF ON OFF OFF
Pre Announce Repeating Bing
OFF OFF ON OFF
Pre Announce
CANCEL
OFF OFF OFF ON
Ding Dong
Pre Announce
ON
ON
ON
ON
Ding Dong
Repeating Bong
OFF ON
ON
ON
Ding Dong
Repeating Bing
ON OFF ON
ON
Ding Dong
CANCEL
ON
ON OFF ON
Repeating Bong Pre Announce
ON
ON
ON OFF Repeating Bong
Ding Dong
OFF OFF ON
ON
Repeating Bong Repeating Bing
OFF ON OFF ON
Repeating Bong
CANCEL
OFF ON
ON OFF
Repeating Bing Pre Announce
ON
ON OFF OFF
Repeating Bing
Ding Dong
ON OFF ON OFF
Repeating Bing Repeating Bong
ON OFF OFF ON
Repeating Bing
CANCEL
The Alert/Evacuation module has multiple chime options, a recordable
voice-over message and adjustable alert to evacuation tone switch-over times.
These options are selectable inside the unit, via the BCD rotary switch and
DIP switches located on the alert/evacuation module (refer to below settings).
ON
OFF
Momentary Alert
& Evac operation
Latched Alert
& Evac operation
1
2
3
4
Voice-over
message ON
Voice-over
message OFF
Not Used
Not Used
Mic recording
enabled
Mic recording
disabled
DIP
SW
1 2 3 4
SW5
1
2
(Maximum 500mA per output)
8
7
6
5
4
3
1
SW4
(Not Used)
16GB
Maximum
Micro SD Card
2
1 2
3
4
1 2
3
4
1 2
3
4
1 2
3
4
1 2
3
4
Aux Input Sensitivity
DIP Switch Settings
SW1
ON OFF
(1) Input 1 0.3V 0.7V
(2) Input 2 0.3V 0.7V
(3) Input 3 0.3V 0.7V
(4) Input 4 0.3V 0.7V
SW2
ON OFF
(1) Input 5 0.3V 0.7V
(2) Input 6 0.3V 0.7V
(3) Input 7 0.3V 0.7V
(4) Input 8 0.3V 0.7V
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
Store
Recall
All Call
Emergency
(All Zones)
A 4481 Communicator
System Busy
Page
Lock On
REDBACK
A 4481
8 Zone Communicator
Version 1.1
Cancel
Store
Recall
All Call
Emergency
(All Zones)
A 4481 Communicator
System Busy
Page
Lock On
REDBACK
A 4481
8 Zone Communicator
Version 1.1
Cancel
PROGRAM
PRESET
CONFIRM
REDBACK
A 4476
A 4476 Preset Wallplate
Max 300m
Max 300m
Max 300m
Max 300m
M 8968C 24V DC 1A
Power Supply
Store
Recall
All Call
Emergency
(All Zones)
A 4481 Communicator
System Busy
Page
Lock On
REDBACK
A 4481
8 Zone Communicator
Version 1.1
Cancel
Store
Recall
All Call
Emergency
(All Zones)
A 4481 Communicator
System Busy
Page
Lock On
REDBACK
A 4481
8 Zone Communicator
Version 1.1
Cancel
M 8968C 24V DC 1A
Power Supply
Store
Recall
All Call
Emergency
(All Zones)
A 4481 Communicator
System Busy
Page
Lock On
REDBACK
A 4481
8 Zone Communicator
Version 1.1
Cancel
Store
Recall
All Call
Emergency
(All Zones)
A 4481 Communicator
System Busy
Page
Lock On
REDBACK
A 4481
8 Zone Communicator
Version 1.1
Cancel
M 8968C 24V DC 1A
Power Supply
CONSOLE 1
ID = 1
CONSOLE 5
ID = 5
CONSOLE 2
ID = 2
CONSOLE 6
ID = 6
CONSOLE 4
ID = 4
CONSOLE 3
ID = 3