red
TECNIKA 28-35
USE AND INSTALLATION MANUAL
Chapter
3
page 11
Technical specifications and dimensions
Technical dept. - All rights reserved - Reproduction prohibited
3.4.
Boiler fuel supply
The boiler must be supplied with the following fuel:
wood logs
, preferably cut, with the following features:
o
pure wood, use of contaminated wood is not allowed (i.e. painted wood, subjected to
chemical treatment or other mineral or organic substances)
o
the length of the wood logs must correspond to the depth of the combustion chamber of the
boiler
(see boiler technical specifications)
o
the crosswise section (diameter) of the wood logs must be: D
≤
200 mm
o
the raw material humidity content must be less than 20% (W
r
≤
20%)
o
wood-based fuel such as sawdust, wood chips and other small combustible particles may be
used in addition to wood logs, but their total amount must be less than 20% of the fuel
loaded into the boiler chamber.
Approximate recommended fuel parameters - cut, pre-dried wood logs
PARAMETERS
UNIT OF MEASURE
VALUES
TYPE OF FUEL
WOOD LOGS
WOOD LOG LENGTH
mm
See previous table
HUMIDITY CONTENT
%
≤
20%
CALORIFIC POWER OF FUEL
USED IN OUR CALCULATIONS
MJ/kg >13.9
kWh/kg >3.9
EXPLANATION:
the maximum percentage of humidity in wood must be 20%. It is advisable to use wood
dried for at least 1 year.