red
PRACTIKA 28-33
USE AND INSTALLATION MANUAL
Chapter 9
page 52
Menu structure
Technical dept. - All rights reserved - Reproduction prohibited
SILENCE THE ALARM ON THE CONTROL PANEL (see paragraph 10.2). REMOVE THE
PELLET LEFT IN THE BRAZIER AND REPEAT THE START-UP PROCESS
If, after a repeated number of start-up attempts, there is still no flame despite a regular supply of pellets,
check the brazier is correctly seated, as it must be
seated perfectly inside its slot and free of any ash
deposits
. If nothing untoward is detected, this means there may be a problem with the boiler components
or ascribable to incorrect installation.
REMOVE THE PELLET FROM THE BRAZIER AND CALL FOR AN AUTHORISED RED
TECHNICIAN.
9.6.
Connecting the room thermostat or storage tank thermostat
The boiler should be connected to an external thermostat with a clean contact. (see figure par.7.4.1)
Thermostat and related electrical cables are under the user's responsibility. We recommend these
connections be made by a specialised technician.