![RED RANGER MONSTRO 8K VV Operation Manual Download Page 152](http://html1.mh-extra.com/html/red-ranger/monstro-8k-vv/monstro-8k-vv_operation-manual_1428145152.webp)
SENSOR SYNC
NOTE:
HDRX
®
is not available when Genlock Sensor Sync is enabled.
Sensor Sync is achieved when an incoming genlock signal is compatible with the monitor output frequency, project
time base, and recording frame rate. In Sensor Sync mode, sensor timing is locked to the genlock signal. Sensor
Sync requires the following synchronized settings:
SETTING
MENU LOCATION PATH
Genlock signal frequency
N/A; external genlock device
HD-SDI monitor output frequency
Menu > Monitoring > Monitors > select monitor
Project Time Base
Menu > Settings > Project > Frame Rate
Recording Frame Rate
Menu > Settings > Project > Frame Rate
SET UP SENSOR SYNC MODE
To set up and enable Sensor Sync Mode, follow the instructions below:
1. Ensure that the Project Time Base and Recording Frame Rate will be compatible with the incoming genlock signal.
2. Connect the
GENLOCK
port on the camera to the device using a 75 ohm BNC cable.
3. Go to
Menu
>
Settings
>
Setup
>
GPIO/Sync
>
Sync
.
4. Select
Genlock
from the
Sensor Sync Mode
drop-down menu.
5. Set up the frequency for the HD-SDI output (select
Auto
to automatically match the HD-SDI output to the current
Project Time Base). For more information, go to
The
GEN
indicator in the Lower Status Row turns green when a compatible genlock signal is present and genlock
is enabled. The SYNC indicator in the Lower Status Row turns green when Sensor Sync is achieved.
REQUIRED CABLE
75 ohm BNC cable (such as the RED HD-SDI Cable, P/N 790-0341)