INSTALLATION

Physical Installation

2

Risk of bodily injury or property damage.

This equipment must not be used by children or persons with 
reduced physical, sensory, or mental abilities, or lacking in expe

-

rience and expertise, unless supervised or instructed. Children 
may not use the equipment, nor may they play with the unit or 
in the immediate vicinity.

Do not use this pump for pumping any liquid intended for 
human consumption.

Make sure that the discharge line of the pump is secure before 
operating pump. If the discharge line is not secured it could 
move.

Release all pressure within the system before disconnecting 
plumbing connections.

Do not add acid or electrolyte to a battery being used—add only 
water, if necessary. Consult the battery manufacturer for any 
additional safety instructions. 

Operation of this equipment requires detailed installation and 
operation instructions provided in this manual for use with this 
product. Read entire manual before starting installation and 
operation.

End User should receive and retain manual for future use.

Keep safety labels clean and in good condition.

Risk of damage to pump or other equipment.

Connect only to a 12 Volt battery.

The pump has been evaluated for use with water only. Pump 
should only be used with liquids compatible with pump compo

-

nent materials. If the pump is used with liquids incompatible 
with the pump components, the liquid can cause failure to the 
electrical insulation system resulting in pump failure.

DO NOT RUN PUMP DRY

. Dry running (without liquid) for more 

than 30 seconds will permanently damage the impeller. Prime 
pump before starting to protect impeller. Be sure to turn off 
pump when liquid supply is exhausted.

Do not submerge motor or mount pump in a location where 
motor will come in contact with water. This pump is not 
designed for use in showers, hot tubs, spas, bilges, or other 
potentially wet locations. 

Do not oil the motor. The pump’s motor housing is sealed. Use of 
oil could cause permanent damage to the pump.

Protect lead wires from sharp objects, hot surfaces, oil and 
chemicals. Avoid kinking the lead wires. Replace or repair dam

-

aged or worn lead wires immediately.

Do not use the lead wires for lifting the pump.

Do not let the unit freeze. Freezing may cause cracking or distor

-

tion that may destroy the unit.

INSTALLATION

Physical Installation

1.

Do not connect the pump to the battery until all plumbing connections are 
complete and the pump is secure.

2. Position the pump on a flat surface and make sure the hoses to be used are 

uncoiled.

Pump should be placed as close to the source of water and battery as 
possible, not more than 7 ft above the water source and not more than 
36 ft from the battery.

If the suction line is longer than 6 ft, or the suction lift is higher than 6 ft 
above the water source, install a foot valve. 

When used in a boat, the pump should not be installed in the bilge.

The motor is designed to be used in a clean, dry location with access to 
an adequate supply of cooling air. Ambient temperature around the motor should not exceed 
104°F (40°C). For outdoor installations, motor must be protected from the elements by a cover 
that does not block airflow to and around the motor. 

3. Attach rigid pipe or reinforced hose to the suction port (opposite the port marked “Outlet Port”). 

Avoid using looped section of pipe or hose that might permit air to become entrapped.

IMPORTANT:

 Using unreinforced hose on the suction side of the pump could cause a loss of prime.

4. Place the end of the suction line or reinforced garden hose into the source of water to be moved.
5. Ensure the suction line is airtight and there are no holes in the pipe or reinforced hose. 
6. Attach a garden hose to the discharge port (marked "Outlet Port"). A regular garden hose may be used 

on the discharge side of the pump.

7. Direct the end of the garden hose where the water is to be relocated. Secure the discharge hose to keep 

it from moving due to water pressure.

3

6

Summary of Contents for RLMPFV12

Page 1: ...Technical Support for a printed copy Specifications Model Phase Volts Amps Watts HP Shut Off RLMPFV12 1 12 VDC 9 110 1 12 38 ft 11 6 m BEFORE GETTING STARTED This equipment should be installed and serviced by technically qualified personnel who are familiar with the correct selection and use of appropriate tools equipment and procedures Failure to comply with national and local electrical and plum...

Page 2: ...ally wet locations Do not oil the motor The pump s motor housing is sealed Use of oil could cause permanent damage to the pump Protect lead wires from sharp objects hot surfaces oil and chemicals Avoid kinking the lead wires Replace or repair dam aged or worn lead wires immediately Do not use the lead wires for lifting the pump Do not let the unit freeze Freezing may cause cracking or distor tion ...

Page 3: ...loose or leaking hoses Any problems should be corrected before pump is returned to service Only qualified electricians or servicemen should attempt to repair this unit Impeller Replacement 1 Remove cover plate mounting screws 2 Remove cover plate and cover plate gasket 3 Slide damaged or worn impeller off motor shaft 4 Clean the inside of the pump head and the cover gasket sealing surface Make cer...

Page 4: ...res Defective motor Replace pump Pump will not prime or loses prime Air leak in suction line Locate and eliminate air leak in suction line Suction lift is too high Reduce the pump height to water source Damaged impeller Replace impeller Refer to Maintenance on page 3 Pump runs but does not dis charge fluid Damaged impeller Replace impeller Refer to Maintenance on page 3 Suction lift is too high Re...

Page 5: ...mmuniquer avec le soutien technique pour en obtenir une copie imprimée Spécifications Modèle Phase Volts Ampères Watts HP Arrêt RLMPFV12 1 12 V CC 9 110 1 12 11 6 m 38 pi AVANT DE COMMENCER Cet équipement doit être installé et entretenu par des techniciens qualifiés capables de choisir et d utiliser les outils les équipements et les procédures appropriés Le non respect des codes électriques et cod...

Page 6: ...it en contact avec de l eau Cette pompe n est pas destinée à être utilisée dans les douches les spas les cales ou d autres emplacements potentiellement mouillés Ne pas graisser le moteur Le carter moteur de la pompe est scellé L utilisation d huiles peut causer des dommages permanents de la pompe N utilisez pas les fils conducteurs pour soulever la pompe Ne laissez pas l unité geler Le gel peut ca...

Page 7: ...esserrées de mauvais alignement de la turbine de pièces fissurées ou cassées de fils conducteurs endommagés ou de tuyaux souples desserrés ou fuyants Toute anormalité doit être corrigée avant que la pompe ne soit remise en service Seuls des électriciens ou des réparateurs qualifiés devraient réparer cet appareil Remplacement de la turbine 1 Retirez les vis de fixation du couvercle 2 Retirez le cou...

Page 8: ...de la batterie Les pinces crocodiles sont corrodées Nettoyez les pinces sur les fils conducteurs Le moteur est défectueux Remplacer la pompe La pompe ne s amorce pas ou perd son amorçage Il y a une fuite d air dans la conduite d aspi ration Localiser et éliminer la fuite d air dans la conduite d aspiration La hauteur d aspiration est trop grande Réduisez la hauteur de la pompe par rapport à la sou...

Page 9: ...o bien llame al departamento de Soporte técnico para obtener una copia impresa Especificaciones Modelo Fase Voltios A Vatios HP Apagado RLMPFV12 1 12 VCC 9 110 1 12 38 pies 11 6 m ANTES DE EMPEZAR La instalación y el mantenimiento de este equipo deben estar a cargo de personal con capacitación técnica El hecho de no cum plir con los códigos eléctricos nacionales y locales y con las recomendaciones...

Page 10: ...aceites puede provocar daños permanentes a la bomba Proteja los cables conductores de objetos afilados superficies calientes aceite y productos químicos Evite torcer los cables conductores Reemplace o repare de inmediato los cables con ductores dañados o desgastados No use los cables conductores para levantar la bomba No deje que la unidad se congele La congelación puede causar agrietamiento o dis...

Page 11: ...cio Solo electricistas o técnicos de servicio calificados pueden intentar reparar esta unidad Reemplazo del impulsor 1 Retire los tornillos de montaje de la cubierta protectora 2 Retire la cubierta protectora y la junta de la cubierta 3 Deslice el impulsor dañado o desgastado fuera del eje del motor 4 Limpie el interior del cabezal de la bomba y la superficie de sellado de la junta de la cubierta ...

Page 12: ...e aire en la línea de succión Ubique y elimine la fuga de aire en la línea de succión La altura de succión es demasiado alta Reduzca la altura de la bomba con respecto a la fuente de agua Impulsor dañado Reemplace el impulsor La bomba fun ciona peronodes carga líquido Impulsor dañado Reemplace el impulsor La altura de succión es demasiado alta Reduzca la altura de la bomba con respecto a la fuente...