background image

/3333

,!-

,!-

F1/F2 Keys

234(5

7$!3/

7$!32

7$!38

4/

42

!$%

$534/

$5342

USER INPUTS

FUNCTION KEYS

83#*5

!:%&

"'

#*

$,3=

5*+&

Rate

Display

Lock-out

Max

Display

Lock-out

Min

Display

Lock-out

Setpoint 1-4

Access

Security

Code

93!%&

#*37

+

%

"'37+%

!%& 

+

,

!%&+$,

!%&'(,

!*7(+

#*57%

Low Update

T

ime

High Update

T

ime

Rate Decimal

Position

Rate Scaling

Display

Rate Scaling

Input

Rate Display

Rounding

Min. Low

Cut-out

"'3%

Max. Capture

Delay T

ime

#*3%

Min. Capture

Delay T

ime

<3333

>3$,%

$,$&#

#B%3=

*7%3=

$7,3=

:5%3=

$,3=

%!53=

Setpoint

Select

Setpoint

Annunciators

Output

Logic

Power-up

State

Setpoint

Action

Setpoint

V

alue

Setpoint

T

racking

%A,3=

Boundary

T

ype

$%)3=

"A$3=

%*443=

%*(3=

%*7%3=

Standby

Operation

Setpoint

Hysteresis

Of

f T

ime

Delay

On T

ime

Delay

T

ime-out

V

alue

C3333

D3333

;345$

Factory

Service Code

=

= Setpoint number

5*+&

PAXR PROGRAMMING QUICK OVERVIEW

Summary of Contents for PAXR

Page 1: ...uctions that appear in this literature or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it If equipment is used in a...

Page 2: ...20 msec Quad Sourcing Open Collector Card Type Four isolated sinking PNP transistors Isolation To Sensor User Input Commons 500 Vrms for 1 min Working Voltage 50 V Not isolated from all other commons...

Page 3: ...r Isolated quad sourcing PNP open collector The card can be installed initially or at a later date Each optional plug in card is shipped with complete installation instructions however programming sho...

Page 4: ...possible from contactors control relays transformers and other noisy components 5 In extremely high EMI environments the use of external EMI suppression devices such as ferrite suppression cores is ef...

Page 5: ...tween the appropriate User Input terminal and User Comm 4 3 INPUT WIRING CAUTION Sensor input common is NOT isolated from user input common In order to preserve the safety of the meter application the...

Page 6: ...xt parameter F1 Function key 1 hold for 3 seconds for Second Function 1 Increment selected parameter value or selections F2 Function key 2 hold for 3 seconds for Second Function 2 Decrement selected p...

Page 7: ...s may be completely restored in Module 9 This is a good starting point for programming problems Most parameters can be left at their Factory Settings without affecting basic start up These parameters...

Page 8: ...Y DESCRIPTION DISPLAY NO Minimum LO NO Maximum HI FACTORY DESCRIPTION DISPLAY DISPLAY DESCRIPTION FACTORY SP 1 Setpoint 1 NO SP 2 Setpoint 2 NO SP 3 Setpoint 3 NO SP 4 Setpoint 4 NO NO Setpoint 4 SP 4...

Page 9: ...grammed for 5 or The setpoint displays can be programmed for 5 or See the following table Accessible only with the Setpoint Plug in card installed Entry of a non zero value will cause the prompt 5 to...

Page 10: ...o function independent of being displayed MAXIMUM CAPTURE DELAY TIME 210 3 010 to 1 seconds When the Rate value is below the present Minimum rate value for the entered amount of time the meter will ca...

Page 11: ...hour is entered by a third less 1200 then Input value is a third less of of pulses per unit The same is true if the Input value is raised or lowered then Display value must be raised or lowered by the...

Page 12: ...e display will default to Select the next setpoint to be programmed and continue the sequence for each setpoint Pressing PAR at will exit Module 6 7 3 SETPOINT OUTPUT LOGIC Normal turns the output on...

Page 13: ...OPERATION Selecting 6 will disable low acting setpoints at a power up until the display value crosses into the alarm off area Once in the alarm off area the setpoint will function according to the con...

Page 14: ...urns to 5 0 Press DSP key to return to the Display Mode This will overwrite all user settings with the factory settings Pressing the PAR and DSP keys at the same time on power up will load the factory...

Page 15: ...OUT CHECK Active lock out user input ENTER Security code requested CERTAIN DISPLAYS ARE LOCKED OUT CHECK Module 3 programming INCORRECT DISPLAY VALUE CHECK Input wiring DIP switch setting input progr...

Page 16: ...ng Display Rate Scaling Input Rate Display Rounding Min Low Cut out 3 Max Capture Delay Time 3 Min Capture Delay Time 3333 3 B 3 7 3 7 3 5 3 3 53 Setpoint Select Setpoint Annunciators Output Logic Pow...

Reviews: