* See Module 2, Exchanging Parameter Lists, for details on programming this value.

DISPLAY

PARAMETER

USER SETTING

FACTORY

SETTING

USr-1

USER INPUT 1

NO

USr-2

USER INPUT 2

NO

USr-3

USER INPUT 3

NO

F1

FUNCTION KEY 1

NO

F2

FUNCTION KEY 2

NO

rSt

RESET KEY

dSPrSt

Sc-F1

2nd FUNCTION KEY 1

NO

Sc-F2

2nd FUNCTION KEY 2

NO

2-FNC

User Input and Function Key Parameters

3-LOC

Display and Program Lockout Parameters

4-rtE

Rate Input Parameters

DISPLAY

PARAMETER

USER SETTING

FACTORY

SETTING

SP-3
SP-4

SETPOINT 3 ACCESS LOCK-OUT

LOC
LOC

LO

rAtE

MIN DISPLAY LOCK-OUT

RATE DISPLAY LOCK-OUT

LOC

rEd

SP-1

HI

SETPOINT 1 ACCESS LOCK-OUT

MAX DISPLAY LOCK-OUT

LOC

LOC

COdE

SP-2

SECURITY CODE

SETPOINT 2 ACCESS LOCK-OUT

0

LOC

rtEINP

RATE SCALING INPUT

1000.0

rOUNd

LO-Udt

RATE DISPLAY ROUNDING

LOW UPDATE TIME

1

1.0

LOCUt

HI-Udt

MINIMUM LOW CUT OUT

HIGH UPDATE TIME

0

2.0

LO-t

rtEdSP

HI-t

rtE dP

MIN CAPTURE DELAY TIME

RATE SCALING DISPLAY

MAX CAPTURE DELAY TIME

RATE DECIMAL POINT

2.0

1000

2.0

0

DISPLAY

PARAMETER

USER SETTING

FACTORY

SETTING

PARAMETER VALUE CHART

Programmer ________________   Date ________

PAXR Rate Meter

Meter# _____________   Security Code __________

SETPOINT 4 ACCESS LOCK-OUT

TROUBLESHOOTING

For further assistance, contact technical support at the appropriate company numbers listed.

PROBLEM

REMEDIES

NO DISPLAY

CHECK

: Power level, power connections

PROGRAM LOCKED-OUT

CHECK

: Active (lock-out) user input

ENTER

: Security code requested

CERTAIN DISPLAYS ARE LOCKED OUT

CHECK

: Module 3 programming

INCORRECT DISPLAY VALUE

CHECK

: Input wiring, DIP switch setting, input programming, input signal level,

user input jumper, lower input signal frequency

USER INPUT NOT WORKING CORRECTLY

CHECK

: User input wiring, user input jumper, Module 2

OUTPUT DOES NOT WORK

CHECK

: Corresponding plug-in card installation, output configuration, output wiring

JITTERY DISPLAY

CHECK

: Wiring is per EMC installation guidelines, input signal frequency, signal quality,

scaling, update time, DIP switch setting

! *#*#

” 

RATE

CHECK

: Lower input signal frequency, reduce rate scaling

MODULES or PARAMETERS NOT ACCESSIBLE

CHECK

: Corresponding plug-in card installation, related controlling parameter selected

ERROR CODE

(

&!! /39

)

PRESS

: Reset key (if unable to clear contact factory.)

0

1.00

0.00

100

0.00

100

NO

OFF

0

HI

OFF

NOr

NO

NOr

SP-4

USER SETTING

1.00

0.00

100

0.00

100

NO

OFF

HI

OFF

NOr

NO

NOr

SP-3

FACTORY

SETTING

USER SETTING

FACTORY

SETTING

0

1.00

0.00

100

0.00

100

NO

OFF

0

SETPOINT HYSTERESIS

HYS-n

HI

OFF

NOr

NO

NOr

SP-2

USER SETTING

1.00

SETPOINT TIME OUT

tOUt-n

0.00

100

SETPOINT ON DELAY

SETPOINT VALUE (B)*

tON-n

0.00

100

SETPOINT OFF DELAY

SETPOINT VALUE (A)

tOFF-n

SP-n

NO

OFF

STANDBY OPERATION

SETPOINT ACTION

Stb-n

ACt-n

HI

OFF

NOr

NO

NOr

SETPOINT BOUNDARY TYPE

SETPOINT POWER UP STATE

SETPOINT OUTPUT LOGIC 

SETPOINT TRACKING

SETPOINT ANNUNCIATORS

tYP-n

SUP-n

OUt-n

trC-n

LIt-n

SP-1

FACTORY

SETTING

USER SETTING

FACTORY

SETTING

PARAMETER

DISPLAY

6-SPt

Setpoint (Alarm) Parameters

Summary of Contents for PAXR

Page 1: ...uctions that appear in this literature or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it If equipment is used in a...

Page 2: ...20 msec Quad Sourcing Open Collector Card Type Four isolated sinking PNP transistors Isolation To Sensor User Input Commons 500 Vrms for 1 min Working Voltage 50 V Not isolated from all other commons...

Page 3: ...r Isolated quad sourcing PNP open collector The card can be installed initially or at a later date Each optional plug in card is shipped with complete installation instructions however programming sho...

Page 4: ...possible from contactors control relays transformers and other noisy components 5 In extremely high EMI environments the use of external EMI suppression devices such as ferrite suppression cores is ef...

Page 5: ...tween the appropriate User Input terminal and User Comm 4 3 INPUT WIRING CAUTION Sensor input common is NOT isolated from user input common In order to preserve the safety of the meter application the...

Page 6: ...xt parameter F1 Function key 1 hold for 3 seconds for Second Function 1 Increment selected parameter value or selections F2 Function key 2 hold for 3 seconds for Second Function 2 Decrement selected p...

Page 7: ...s may be completely restored in Module 9 This is a good starting point for programming problems Most parameters can be left at their Factory Settings without affecting basic start up These parameters...

Page 8: ...Y DESCRIPTION DISPLAY NO Minimum LO NO Maximum HI FACTORY DESCRIPTION DISPLAY DISPLAY DESCRIPTION FACTORY SP 1 Setpoint 1 NO SP 2 Setpoint 2 NO SP 3 Setpoint 3 NO SP 4 Setpoint 4 NO NO Setpoint 4 SP 4...

Page 9: ...grammed for 5 or The setpoint displays can be programmed for 5 or See the following table Accessible only with the Setpoint Plug in card installed Entry of a non zero value will cause the prompt 5 to...

Page 10: ...o function independent of being displayed MAXIMUM CAPTURE DELAY TIME 210 3 010 to 1 seconds When the Rate value is below the present Minimum rate value for the entered amount of time the meter will ca...

Page 11: ...hour is entered by a third less 1200 then Input value is a third less of of pulses per unit The same is true if the Input value is raised or lowered then Display value must be raised or lowered by the...

Page 12: ...e display will default to Select the next setpoint to be programmed and continue the sequence for each setpoint Pressing PAR at will exit Module 6 7 3 SETPOINT OUTPUT LOGIC Normal turns the output on...

Page 13: ...OPERATION Selecting 6 will disable low acting setpoints at a power up until the display value crosses into the alarm off area Once in the alarm off area the setpoint will function according to the con...

Page 14: ...urns to 5 0 Press DSP key to return to the Display Mode This will overwrite all user settings with the factory settings Pressing the PAR and DSP keys at the same time on power up will load the factory...

Page 15: ...OUT CHECK Active lock out user input ENTER Security code requested CERTAIN DISPLAYS ARE LOCKED OUT CHECK Module 3 programming INCORRECT DISPLAY VALUE CHECK Input wiring DIP switch setting input progr...

Page 16: ...ng Display Rate Scaling Input Rate Display Rounding Min Low Cut out 3 Max Capture Delay Time 3 Min Capture Delay Time 3333 3 B 3 7 3 7 3 5 3 3 53 Setpoint Select Setpoint Annunciators Output Logic Pow...