background image

GENERAL DESCRIPTION

The PAXR (PAX Rate Panel Meter) offers many features and performance

capabilities to suit a wide range of industrial applications.  The optional Plug-in
Setpoint Alarm Cards allow the opportunity to configure the meter for alarms if
that is a requirement.

The PAXR meter accepts digital inputs from a variety of sources including

outputs from CMOS or TTL circuits and all standard RLC sensors. The
maximum input signal is 34 KHz. 

The meter provides three different display indications.  These include a Rate

Display, Max Display, and Min Display. Annunciators indicate which display is
being shown.

The front panel keys and three user inputs are programmable to perform

various meter functions.  One of the functions includes exchanging parameter
lists, allowing double the number of programmable setpoint.

The meter can have up to four setpoint outputs, determined by the Plug-in

cards. The Plug-in cards provide dual FORM-C relays (5 A), quad FORM-A
relays (3 A) or either quad sinking or quad sourcing open collector logic
outputs. The outputs are assigned to the rate display value. The outputs can also
be independently configured to suit a variety of control and alarm requirements.

Once the meter has been initially configured, the parameter list may be

locked out from further modification entirely, or only the setpoint can be made
accessible.  This lockout is possible through a security code or user input.

The meter has been specifically designed for harsh industrial environments.

With a NEMA 4X/IP65 sealed bezel and extensive testing to meet CE
requirements, the meter provides a tough yet reliable application solution.

SAFETY SUMMARY

All safety related regulations, local codes and instructions that appear in this

literature or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.

Do not use this meter to directly command motors, valves, or other actuators

not equipped with safeguards. To do so can be potentially harmful to persons or
equipment in the event of a fault to the unit.

SPECIFICATIONS

1. 

DISPLAY

: 5 digit, 0.56" (14.2 mm) red LED

2. 

POWER

:

AC Versions (PAXR0000):

AC Power: 85 to 250 VAC, 50/60 Hz, 12 VA
Isolation: 2300 Vrms for 1 min. to all inputs and outputs. (300 V working)

DC Versions (PAXR0010):

DC Power: 11 to 36 VDC, 7 W 
AC Power: 24 VAC, ± 10%, 50/60 Hz, 9 VA
Isolation: 500 Vrms for 1 min. to all inputs and outputs (50 V working)

3. 

SENSOR POWER

: 12 VDC, ±10%, 100 mA max. Short circuit protected.

4. 

ANNUNCIATORS

:

!

- Rate

"

- Maximum (High) Rate

#

- Minimum (Low) Rate

SP1 - Setpoint 1 Output State
SP2 - Setpoint 2 Output State
SP3 - Setpoint 3 Output State
SP4 - Setpoint 4 Output State

5. 

KEYPAD

: 3 programmable function keys, 5 keys total.

6. 

RATE DISPLAY

:

Accuracy: ± 0.01%
Minimum Frequency: 0.01 Hz
Maximum Frequency: 34 KHz
Maximum Display: 5 digits: 99999
Adjustable Display (low) Update: 0.1 to 99.9 seconds
Over Range Display: “r OLOL”

1

MODEL PAXR-1/8 DIN RATE PANEL METER

!

5-DIGIT LED DISPLAY

!

RATE INDICATION

!

PROGRAMMABLE FUNCTION KEYS / USER INPUTS 

!

FOUR SETPOINT ALARM OUTPUTS (W/Plug-in card)

!

NEMA 4X/IP65 SEALED FRONT BEZEL

CAUTION: Read complete

instructions prior to installation

and operation of the unit.

CAUTION: Risk of electric shock.

DIMENSIONS  In inches (mm)

Note: Recommended minimum clearance (behind the panel) for 

mounting clip installation is 2.1" (53.4) H x 5.0" (127) W.

Bulletin No.  PAXR-A
Drawing No.  LP0511
Released  7/01

Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion-controls.com

UL Recognized Component,
File # E179259

Summary of Contents for PAXR

Page 1: ...uctions that appear in this literature or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it If equipment is used in a...

Page 2: ...20 msec Quad Sourcing Open Collector Card Type Four isolated sinking PNP transistors Isolation To Sensor User Input Commons 500 Vrms for 1 min Working Voltage 50 V Not isolated from all other commons...

Page 3: ...r Isolated quad sourcing PNP open collector The card can be installed initially or at a later date Each optional plug in card is shipped with complete installation instructions however programming sho...

Page 4: ...possible from contactors control relays transformers and other noisy components 5 In extremely high EMI environments the use of external EMI suppression devices such as ferrite suppression cores is ef...

Page 5: ...tween the appropriate User Input terminal and User Comm 4 3 INPUT WIRING CAUTION Sensor input common is NOT isolated from user input common In order to preserve the safety of the meter application the...

Page 6: ...xt parameter F1 Function key 1 hold for 3 seconds for Second Function 1 Increment selected parameter value or selections F2 Function key 2 hold for 3 seconds for Second Function 2 Decrement selected p...

Page 7: ...s may be completely restored in Module 9 This is a good starting point for programming problems Most parameters can be left at their Factory Settings without affecting basic start up These parameters...

Page 8: ...Y DESCRIPTION DISPLAY NO Minimum LO NO Maximum HI FACTORY DESCRIPTION DISPLAY DISPLAY DESCRIPTION FACTORY SP 1 Setpoint 1 NO SP 2 Setpoint 2 NO SP 3 Setpoint 3 NO SP 4 Setpoint 4 NO NO Setpoint 4 SP 4...

Page 9: ...grammed for 5 or The setpoint displays can be programmed for 5 or See the following table Accessible only with the Setpoint Plug in card installed Entry of a non zero value will cause the prompt 5 to...

Page 10: ...o function independent of being displayed MAXIMUM CAPTURE DELAY TIME 210 3 010 to 1 seconds When the Rate value is below the present Minimum rate value for the entered amount of time the meter will ca...

Page 11: ...hour is entered by a third less 1200 then Input value is a third less of of pulses per unit The same is true if the Input value is raised or lowered then Display value must be raised or lowered by the...

Page 12: ...e display will default to Select the next setpoint to be programmed and continue the sequence for each setpoint Pressing PAR at will exit Module 6 7 3 SETPOINT OUTPUT LOGIC Normal turns the output on...

Page 13: ...OPERATION Selecting 6 will disable low acting setpoints at a power up until the display value crosses into the alarm off area Once in the alarm off area the setpoint will function according to the con...

Page 14: ...urns to 5 0 Press DSP key to return to the Display Mode This will overwrite all user settings with the factory settings Pressing the PAR and DSP keys at the same time on power up will load the factory...

Page 15: ...OUT CHECK Active lock out user input ENTER Security code requested CERTAIN DISPLAYS ARE LOCKED OUT CHECK Module 3 programming INCORRECT DISPLAY VALUE CHECK Input wiring DIP switch setting input progr...

Page 16: ...ng Display Rate Scaling Input Rate Display Rounding Min Low Cut out 3 Max Capture Delay Time 3 Min Capture Delay Time 3333 3 B 3 7 3 7 3 5 3 3 53 Setpoint Select Setpoint Annunciators Output Logic Pow...