-5-
Released 2018-01-16
Drawing No. LP0749
4.0 r
evIeWIng
the
F
ront
B
uttons
anD
D
IsPlay
B
A
RST
SEL
PAR
1
SP
2
SP
OPERATING MODE DISPLAY DESIGNATORS
“A”
- Counter A value
“B”
- Counter B value (dual count or batch)
- Rate value is displayed with no designator
“SP1” - Indicates setpoint 1 output status.
“SP2” - Indicates setpoint 2 output status.
Pressing the
SEL
button toggles the meter through the selected displays. If display scroll is enabled, the display will toggle automatically every four
seconds between the enabled display values.
PROGRAMMING MODE ENTRY (PAR BUTTON)
It is recommended all programming changes be made off line, or
before installation. The meter normally operates in the Display Mode. No
parameters can be programmed in this mode. The Programming Mode
is entered by pressing the
PAR
button. If it is not accessible, then it is
locked by either a security code or a hardware lock.
MODULE ENTRY (SEL & PAR BUTTONS)
The Programming Menu is organized into four modules. These
modules group together parameters that are related in function. The
display will alternate between
and the present module. The
SEL
button is used to select the desired module. The displayed module is
entered by pressing the
PAR
button.
MODULE MENU (PAR BUTTON)
Each module has a separate module menu (which is shown at the
start of each module discussion). The
PAR
button is pressed to advance
to a particular parameter to be changed, without changing the
programming of preceding parameters. After completing a module, the
display will return to
. Programming may continue by accessing
additional modules.
SELECTION / VALUE ENTRY
For each parameter, the display alternates between the present
parameter and the selections/value for that parameter. The
SEL
and
RST
buttons are used to move through the selections/values for that parameter.
Pressing the
PAR
button, stores and activates the displayed selection/
value. This also advances the meter to the next parameter.
For numeric values, the value is displayed with one digit flashing
(initially the right most digit). Pressing the
RST
button increments the digit
by one or the user can hold the
RST
button and the digit will automatically
scroll. The
SEL
button will select the next digit to the left. Pressing the
PAR
button will enter the value and move to the next parameter.
PROGRAMMING MODE EXIT (PAR BUTTON)
The Programming Mode is exited by pressing the
PAR
button with
displayed. This will commit any stored parameter changes to memory
and return the meter to the Display Mode. (If power loss occurs before
returning to the Display Mode, verify recent parameter changes.)
PROGRAMMING TIPS
It is recommended to start with Module 1 and proceed through each
module in sequence. When programming is complete, it is recommended
to record the parameter programming and lock out parameter programming
with the user input or programming security code.
FACTORY SETTINGS
Factory Settings may be completely restored in Module 3. This is
useful when encountering programming problems.
ALTERNATING SELECTION DISPLAY
In the explanation of the modules, the following dual display with
arrows will appear. This is used to illustrate the display alternating
between the parameter on top and the parameter’s Factory Setting on
the bottom. In most cases, selections and values for the parameter will
be listed on the right.
Indicates Program Mode Alternating Display
Factory Settings are shown.
Parameter
Selection/Value
5.0 P
rograMMIng
the
M
eter
Setpoint
Output
Parameters
Input Setup
Parameters
DISPLAY
MODE
Display and Front
Panel Key
Parameters
PAR
SEL
PAR
PAR
PAR
PAR
Rate Setup
Parameters
OVERVIEW
PROGRAMMING MENU
BUTTON
DISPLAY MODE OPERATION
PROGRAMMING MODE OPERATION
PAR
Access Programming Mode
Store selected parameter and index to next parameter
SEL
Index display through enabled values
Advance through selection list/select digit position in
parameter value
RST
Resets count display(s) and/or outputs
Increment selected digit of parameter value