background image

-6-

Drawing No. LP0749 

Released 2018-01-16

COUNTER A DECIMAL POSITION

This selects the decimal point position for Counter A. The selection will 

also affect Counter A scale factor calculations.

COUNTER A SCALE FACTOR

The number of input counts is multiplied by the scale factor to obtain 

the desired process value. A scale factor of 1.0000 will result in the 

display of the actual number of input counts. (Details on scaling 

calculations are explained at the end of this section.)*



 to 



COUNTER B DECIMAL POSITION

This selects the decimal point position for Counter B. The selection will 

also affect Counter B scale factor calculations.



























COUNTER A COUNT LOAD VALUE

Counter A resets to this value if Reset to Count Load action is 

selected. To enter a negative Count Load value, increment digit 6 to 

display a “-” sign.*



 to 





 



PAR

 

Dual Count or Batch 

Only

Counter B 

Scale Factor

Counter A 

Reset Action

 

Counter A 

Decimal Point

Count 

Mode

Counter B 

Decimal Point

Counter A 

Scale Factor

Dual Count or 

Batch Only

Counter B 

Batch Count 

Enable

 

Counter A 

Count Direction

Counter Reset 

at Power-up

 

User Input 

Function

User Input 

Assignment

Counter A 

Count Load 

Value

5.1  MoDule 1 - I

nPut

 s

etuP

 P

araMeters

 (



)

PARAMETER MENU

COUNT MODE

Select the count mode that corresponds with your application. The 

input actions are shown in the boxes below. For simple counting 

applications, it is recommended to use Count with Direction for the count 

mode. Simply leave the direction input unconnected.

 

 



 



 

 



Shaded area selections only apply when Counter B is enabled (Dual 

Count mode or batch counter).

Counter A Subtract

Counter A Add

Counter A Add

Counter A Add

Quad A

Count A

Quad A

Count A

Quad A

Count A

Counter B Add

Counter A Add

Counter A Add

Rate only

Counter A Direction

Counter A

INPUT B ACTION

INPUT A ACTION



2 Input Add/Subtract



2 Input Add/Add

 

Quadrature x4

 

Quadrature x2

 

Quadrature x1



Dual Counter



Rate/Counter

 

Count with Direction

DISPLAY

MODE

Note: The Rate indicator signal is derived from Input A in all count modes.

 

 

COUNTER A RESET ACTION





When Counter A is reset, it returns to Zero or Counter A Count Load 

value. This reset action applies to all Counter A resets, except a Setpoint 

generated Counter Auto Reset programmed in Module 4.

 



COUNTER B BATCH COUNT ENABLE





The Counter B Batch Count function internally counts the number of 

output activations of the selected setpoint(s). The count source for the 

batch counter can be SP1, SP2 or both. Batch counting is available in 

all count modes except Dual Counter, which uses an external input 

signal for Counter B.

COUNTER A COUNT DIRECTION





Reverse (



) switches the normal Counter A count direction shown 

in the Count Mode parameter chart.













*For value entry instructions, refer to selection/value entry in the 

Programming The Meter section.

Summary of Contents for PAX Lite PAXLCR

Page 1: ...MARY All safety regulations local codes and instructions that appear in this and corresponding literature or on equipment must be observed to ensure personal safety and to prevent damage to either the...

Page 2: ...Both inputs allow selectable active low or active high logic and selectable input filtering for low frequency signals or switch contact debounce Input A Logic level or magnetic pickup signals Trigger...

Page 3: ...uctive loads and to minimize radiated and conducted noise EMI some type of contact protection network is normally installed across the load the contacts or both The most effective location is across t...

Page 4: ...C DC AC DC 2 1 ON 3 4 MAGNETIC PICKUP INPUT B COMMON INPUT A COMMON 4 5 6 7 5 24V EXC 3 to 2 5 mA MAX Resistor to Limit Current ON 1 2 3 4 AC 5 INPUT A INPUT B COMMON 7 6 5 24V EXC COMMON 3 4 1 2 ON 3...

Page 5: ...his also advances the meter to the next parameter For numeric values the value is displayed with one digit flashing initially the right most digit Pressing the RST button increments the digit by one o...

Page 6: ...ut actions are shown in the boxes below For simple counting applications it is recommended to use Count with Direction for the count mode Simply leave the direction input unconnected Shaded area selec...

Page 7: ...edths Scale Factor Desired Display Units x Decimal Point Position Number of Pulses Given that 128 pulses are equal to 1 foot display total feet with a one hundredth resolution Scale Factor 1 00 x 100...

Page 8: ...ponding Scaling Input value These values are internally plotted to a Display value of 0 and Input value of 0 0 Hz A linear relationship is formed between these points to yield a rate display value tha...

Page 9: ...tensity Programming any Security Code other than 0 requires this code to be entered at the prompt in order to access Full Programming mode Quick Programming mode if enabled is accessed before the prom...

Page 10: ...e model and version x x of the meter The display then returns to Press the PAR button to exit the module VIEW MODEL AND VERSION DISPLAY Select the display to which the Setpoint is assigned SETPOINT AS...

Page 11: ...off at O1 The setting only applies if Setpoint 1 Output Action is programmed for timed output SETPOINT 2 OUTPUT OFF AT SETPOINT 1 SP2 Only High Acting Boundary Type activates the output when the assi...

Page 12: ...int Assignment Setpoint Enable Setpoint Output Action Setpoint Annunciator SP1 Only Setpoint Value Setpoint Output Time out Setpoint Output Logic Exit Programming Counter Auto Reset Setpoint Boundary...

Page 13: ...POE CUB4LP40 SLX 8ES 1 TORF1000 WF1000BF FANWAND721SMA FCOPPER SFP 100 PSDR060W SLX 5ES 1 309FXE ST 15 CRM000CMCMOD0000 CRM000CMDN000000 CR10001000000210 CR30001000000420 PAXDP000 NT24K 16M12 POE PT N...

Reviews: