Malfunctions
8
BAL_K32_K42_Z_EN_2V5_BLA_121-006454230
41 / 46
151
Test error Horizontal
light barrier Rotor blade
2 (OP-HSR2)
– ErrorStop, Immediate stop of
the rotation
– Perform reset
– If not successful, contact service
OP-HSR2 test error
152
Test error flow sensor
rotor blade 1 (OP-VLS1)
– ErrorStop, Immediate stop of
the rotation
– Perform reset
– If not successful, contact service
OP-VLS1 test error
153
Test error flow sensor
rotor blade 2 (OP-VLS2)
– ErrorStop, Immediate stop of
the rotation
– Perform reset
– If not successful, contact service
OP-VLS2 test error
154
Horizontal light barrier
rotor blade 1 (OP-
HSR1)
– OptoStop, Immediate stop of
the rotation
– Remove object from the detection range
of the sensor
– Check sensor for contamination, clean if
possible
– Perform reset
– If not successful, contact service
OP-HSR1 active
155
Horizontal light barrier
rotor blade 2 (OP-
HSR2)
– OptoStop, Immediate stop of
the rotation
– Remove object from the detection range
of the sensor
– Check sensor for contamination, clean if
possible
– Perform reset
– If not successful, contact service
OP-HSR2 active
156
Stormlock (AuxIn)
– Immediate stop of the rota-
tion
– Release of the Stormlock in-
terlocks
– Check / reset switch
– Perform reset
– If not successful, contact service
AUX-IN Stormlock act-
ive
157
Emergency open
(AuxIn)
– Immediate stop of the rota-
tion
– Release of the escape route
via HST200
– Check / reset switch
– Perform reset
– If not successful, contact service
AUX-IN Emerg. Exit act-
ive
158
Vertical sensor STOP
rotor blade 1 (OP-
VSR12)
– OptoStop, Immediate stop of
the rotation
– Remove object from the detection range
of the sensor
– Check sensor for contamination, clean if
possible
– Perform reset
– If not successful, contact service
VSR1_STOP active
159
Vertical sensor STOP
rotor blade 2 (OP-
VSR22)
– OptoStop, Immediate stop of
the rotation
– Remove object from the detection range
of the sensor
– Check sensor for contamination, clean if
possible
– Perform reset
– If not successful, contact service
VSR2_STOP active
160
Vertical sensor STOP
rotor blade 3 (OP-
VSR32)
– OptoStop, Immediate stop of
the rotation
– Remove object from the detection range
of the sensor
– Check sensor for contamination, clean if
possible
– Perform reset
– If not successful, contact service
VSR3_STOP active