background image

SLP-UL-M-KIT

Doc # 20094_E

I N S T A L L A T I O N   I N S T R U C T I O N S

Visit our website for more details

www.CommandAccess.com

U.S. Customer Support

1-888-622-2377

Canada Customer Support

1-855-823-3002

A.

Kit Includes

A. 

1- Motor Mount Assembly w/ MM4S series module

B. 

2 -Phillips Screws

C. 

1 - Push & Go Connector

D.  1- MM4S switch program sticker

E. 

1 -  5/64” Hex Wrench

F. 

1 - 5/32” Drill Bit

G.  1 - 8’ Lead w/ VD Connector

Tools Required

•  Power Drill

The Command Access SLP-UL-M-KIT is a field installable motorized latch-pullback kit for the 

Sargent 80 series.

B.

C.

D.

E.

E.

Scan or Click here 

Installation Video

F.

G.

Summary of Contents for SLP-UL-M-KIT

Page 1: ...23 3002 A Kit Includes A 1 Motor Mount Assembly w MM4S series module B 2 Phillips Screws C 1 Push Go Connector D 1 MM4S switch program sticker E 1 5 64 Hex Wrench F 1 5 32 Drill Bit G 1 8 Lead w VD Connector Tools Required Power Drill The Command Access SLP UL M KIT is a field installable motorized latch pullback kit for the Sargent 80 series B C D E E Scan or Click here Installation Video F G ...

Page 2: ...e push pad apply power i e presenting the credential to the reader Step 3 Continue to keep pad depressed the device will beep 6 times After the beeps have stopped release the pad and now the adjustment is complete If not to your liking repeat the three steps That s all there is to it Setting PTS Make sure to set PTS before finishing installation Important Info Input Voltage 24VDC 10 Wire gauge Min...

Page 3: ...NTROL SYSTEM NO VOLTAGE LOCKING HARDWARE CAT Electrified Exit Device Installation Example Recommended Power Supplies All Command Access exit devices field installable kits have been thoroughly cycle tested with Command Access power supplies at our factory For more information click here or go to our website ...

Page 4: ...STEP 1 Disassemble Exit Device A Remove End Cap Filler Plate B Remove 4 screws from baserail C Partially slide push pad off approx 2 3 D Using 5 32 drill bit Open up the 2 back screw holes 3 4 ...

Page 5: ...STEP 2 Install Motor Mount A Attach the link assembly to the end of the activating bracket Next place activating bracket into center of the motor mount C Re install metal rod securing activating bracket to motor mount B Secure link assembly to activating bracket with Hex wrench provided Activating Bracket Metal Rod AB Mount Link Assembly Baserail ...

Page 6: ...ired setting Recommend to fully depress and release 5 giving the device room for changing door conditions Step 2 While depressing the push pad apply power i e Presenting the credential to the reader Step 3 Continue to keep pad depressed the device will beep 6 times After the beeps have stopped release the pad and now the adjustment is complete If not to your liking repeat the 3 steps Setting PTS S...

Reviews: