- 39 -
Press the "Return" key to return to Alarm Setup menu to enter the Linkage Setup interface. You can select none/
output 1/output2 from the linkage setup menu. 12V of high level is generated to drive other optoelectronic
devices when the related alarm is triggered. (For detailed connection method, please refer to alarm input/output
cable connection).
Step 7: Motion Detection
(
coming soon
)
Press the "Return" key to return to the Alarm Setup menu to enter the Motion Detection interface. Within the
detection area, you can use your remote control to select two points as diagonal to define a detection area.
Within the user defined area, when there is an object moving, the system will give an alarm when it is detected.
A user can search motion detection alarm events under "Configuration -> Log Search", naming "CHL
MD alarm".
Open to
record related
alarm logs