51
INJECTOR AND PILOT REMOVAL INSTRUCTIONS
(continued)
Replace media as per media fitment Instructions.
Refit door. Check door seal is sitting correctly. Fit screws to seal
DO NOT OVERTIGHTEN SCREWS – Hand tight is sufficient for door to seal.
Turn gas isolation valve off.
Turn on electrical supply.
Turn on appliance and perform dry test run, allow appliance to spark, check for correct sparking
location and frequency.
Turn off appliance.
Turn on gas isolation valve.
Turn appliance on and allow appliance to ignite.
Check gas pressures.
Check for gas leaks.
Check for correct operation, cross ignition of burners and flame. After 10minutes check flame
color. Flame should be blue with yellow tipping, Tall blue or fully yellow flames indicate incorrect
burner setup. Cross ignition should be smooth with no “woofing” or explosive delays.
SHOULD THE APPLIANCE NOT OPERATE CORRECTLY - TURN APPLIANCE
OFF, ISOLATE GAS AND ELECTRICTY SUPPLY AND CONTACT GLEN DIMPLEX
SERVICE.
Turn off appliance.
Disconnect manometer and tighten close test point.
Check for any gas leaks.
Refit lower electrical cover.
Refit lower panel.
Refit glass safety screen. (Note 2 persons required).
Advise customer on correct operation and isolation of appliance in the event of a fault.