INJECTOR AND PILOT REMOVAL INSTRUCTIONS
(continued)
Apply thread sealant to injector threads. Ensure no sealant can block the injector. Fit injectors
and tighten. NOTE INJECTOR SIZE AND LOCATION.
20.
PILOT
•
Remove pilot gas pipe connection,
•
Remove sensor lead and spark lead (10mm spanner required)
•
Unscrew pilot bracket from the burner base.
21. Remove pilot orifice from pilot or
replace whole pilot assembly with
correct gas type.