BASIC OPERATION
Propane
ULPG
Natural Gas
Min. Inlet Pressure
2.5 kPa
2.5 kPa
1.00 kPa
Max Inlet Pressure
5.0 kPa
5.0 kPa
5.00 kPa
Manifold Pressure
2.0 kPa
2.2 kPa
1.00 kPa
Front Burner Jet size
Ø1.3
Ø1.25
Ø4.0
Rear Burner Jet size
Ø1.3
Ø1.25
Ø4.0
Front Burner Aeration Hole
11mm x 2 off per burner
11mm x 2 off per burner
Ø5mm x 2 holes
(NO COLLAR FITTED)
(NO COLLAR FITTED)
Collar must be fitted -1 off per burner
Rear Burner Aeration Hole
11mm x 2 off per burner
11mm x 2 off per burner
Ø5mm x 2 holes
(NO COLLAR FITTED)
(NO COLLAR FITTED)
Collar must be fitted -1 off per burner
Mj/hour
40
40
49