Wall cladding around fire
The temperature of the wall directly above the heater does get hot and hence may discolour paint
finishes.
Some dark coloured exhaust stains may also become visible directly above the fire due to
exhaust. In most cases this can be cleaned off with water and a brush.
Minimum install height
The fire has ventilation gaps behind the fascia at the top and bottom. These must not be blocked,
so ensure there is a gap of at least 30mm between the bottom of the fascia and anything below.
Types of Installation
This appliance shall only be used in an above ground open-air situation with natural ventilation,
without stagnant areas, where gas leakage and products of combustion are rapidly dispersed by
wind and natural convection.
Certain materials or items, when placed under or near the appliance, will be subjected to radiant
heat and could become damaged.
The following installation diagrams are Real Flame IO1000 recommendations only and may or
may not comply with your local council standards. Please check with your local council for actual
building standards.
Typically an outdoor space is not enclosed but, any enclosure in which the appliance is used
should comply with one of the following:
1.
An enclosure with walls on all sides, but at least one permanent opening at ground level and
no overhead cover.