![Real Flame EXURO IO1000 Installation & Operating Manual Download Page 25](http://html1.mh-extra.com/html/real-flame/exuro-io1000/exuro-io1000_installation-and-operating-manual_1425123025.webp)
GAS CONVERSION
(continued)
25
Step Five
Change the two jets with
the conversion jets
supplied in kitset. Cover
the existing gas type label
with the new gas type label
sup-plied in kitset. Ensure
serial number and date of
manufacture are still
visible. Write your name,
company (if appropriate)
and date of conversion on
new label with permanent
marker.
Step Six
Replace the pilot jet with
the correct one supplied in
the kit (See the table
below).
Note: You will have to
remove the cover from
behind the pilot assembly,
it may be helpful to remove
the control tray completely
for best access.
Step Seven
Take the regulator spring
out of the regulator by
unscrewing the pressure
adjustment knob
completely. Swap regulator
spring with the new spring
that is supplied in
conversion kitset. Replace
adjustment screw and
reset gas pressure as per
the settings below.
Gas
NG
Propane
ULPG
Pilot Jet
Ø0.45
Ø0.30
Ø0.30
Front Jet
Ø4.0
Ø1.3
Ø1.25
Rear Jet
Ø4.0
Ø1.3
Ø1.25