GAS CONVERSION
24
Warning: Before starting the gas conversion, ensure that the fireplace is cool.
Step One
Remove the fascia lifting it upwards and outwards. Unplug the cable at the bottom of the fascia
and then finish removing the fascia. This will give you access to remove the Burners and Stone
tray.
Step Two
Remove all of the coals
and the two screws holding
the burner clamps in place,
remove the clamps.
Step Three
Remove the two screws
holding the glass feature
tray in place and lift it out.
Step Four
Lift out both burners, this
will give you access to the
jets (spuds).