Autoset Programming
Real Carriage Door & Sliding Hardware Copyright 2020© all rights reserved
same way
7. Run the two sets of wires (6) from the safety
sensors to the ceiling control unit
• Use staples to keep wires in place
8. Connect to control unit
Autoset Programming
Red Limit Stop
1. Disengage the motor
• Pull the red chord (emergency release) until
it disengages. This will allow you to move the
door freely to see where the door needs to stop
2. Place the doors in open position
3. Position the red stop accordingly
• Tighten the limit back down
4.
Place the doors in the halfway open position
• Re-engage the motor by pulling the red
emergency release chord
Powering Up the Unit
Do not plug the control unit into the outlet until the
installation is complete to prevent damage to the
opener. The outlet may not exceed 69” away from
the control unit.
Autoset
The operator will automatically adjust the
programmed close limit one inch shorter than