Page 18
Photo Eyes
Real Carriage Door & Sliding Hardware Copyright 2020© all rights reserved
1. Locate a reliable trigger point for each door
• Mount the wicket switch
2. Route the wire above the opening to the
opposite motor carriage
• Take special care that the wire will not get
pinched or bind
3. Wire in the wicket
switch to the wicket
door fuse terminal, see
graphic
• It is on the bottom
left of the board, refer to page 8 for more
information
Inserting ACCU (battery backup)
The battery pack can help with approximately 5
cycles within 12 hours of a power failure.
1. Make sure the unit is unplugged
2. Loosen the screw on the control unit cover and
gently lift upwards to remove cover
3. Unplug the connection cable for the membrane
keypad from the unit
4.
Place the battery pack in the control unit cover
and fasten with the two cable binders
5. Plug the battery pack plug into the ACCU
battery slot on the control board
6. Set DIP switch 3 to “ON” on the control unit only
7.
Plug the connection cable for the membrane
keyboard back into the circuit board
8. Place control unit cover back
9.
Screw on cover
Emergency Release Cord
1. Adjust the emergency release chord to the
length you need. See below instructions
Photo Eyes
The 2-wire safety sensors must be connected to
the Control Housing Unit. Initial Operation is not
possible without the safety sensors. The photo eyes
are automatically detected during initial operation.
• If you want to use your own wires you can, be
sure to use 22 gauge.
• The photo eyes are labeled with colored
stickers.
• The green is the sender
• The red is the receiver
Positioning of the Photo Eyes
• The lights should be solid when they are
properly connected, if they are blinking it means
they have power but are not aligned properly.