RDC6585PC Control System manual
V1.0
SHENZHEN RUIDA TECHNOLOGY
61
Laser Enable
: When double lasers are used, then each laser can be respectively
enabled or disabled.
Minimum Power
Maximum Power
Laser PWM Frequency
Pre-generation Frequency Enable
Pre-generation Frequency
Pre-generation pulse scale
: When the laser Pre-generation function is enable, then
set the Pre-generation Frequency and the Pre-generation pulse scale.
Signal level
: To dedicate the valid level of opening laser signal. In RF-laser, the
parameter is invalid, in glass tube laser, the
‘
Low
’
level is recommended.
Water Protector Enabled
: When the water protector is enabled, the mainboard will
detect the input port of water protector. If this port is of low level, it will be deemed normal; if
this port is of high level, the mainboard will forcibly close the laser to suspend the work in
progress and the system will warn. If the water protector is not enabled, the mainboard will not
detect the input port of water protector and so the water protector can be unconnected.
Laser PWM Frequency is used to set the pulse frequency of control signal used by this laser, in
general, glass tube is about 20KHZ, RF laser is about 5KHZ; the maximum/minimum power (%) is
used to set the limit power of this laser, that is to say, during the operation, the maximum power set
by the user can
’
t be higher than that set here and the minimum power set by the user can
’
t be less
than that set here, either. When a laser
’
s power is attenuated, then the laser attenuation quotiety
may be set
If it is only provided with the single laser, it can show the one-path parameter.
(
3
)
Other manufacturer parameters
Machine configuration
Machine Type
: In most cases, the general engraving machine should be selected and
other types used for specific purposes.
Transmission Mode
: generally the
“
Belt Stepping Type
”
should be made choice of. The
Prompt