Compass
STD 22
Installation and Service manual
Compass STD 22
85
Edition: May 20, 2005
3646/110--233.DOC010302
3.3.1.3
Filling with distilled water and supporting liquid.
(see Figure 46)
-- Undo the three plastic screws (Figure 46/1--3) on the upper outer sphere
distilled water
filling tool
supporting liquid
vent
1
2
3
Figure 46
: Filling with liquids
-- Fit the supplied filling device on the distilled water bottle.
-- Pour in all the distilled water (230 cm
3
) (look for the identifying label on the outer
sphere).
-- Re-close the distilled water filling opening with the screw, check that it is properly
sealed.
-- Remove the filling device from the distilled water bottle and attach it to the supporting
liquid bottle.