Compass
STD 22
Installation and Service manual
Compass STD 22
Compass STD 22 Compact
143
Edition: Sept. 13, 2005
3646/110--233.DOC010302
Serial
No.
Comments, Information
Indications
9
Check connected course receivers (check of follow--up function) and check
of RoT.
The check of RoT is only possible at RoT--Indicators which are connected to
the Distribution Unit.
Switch B 37 (DIP switch)
1 2 3 4 5 6 7 8
OPEN
B38
B 39
1X
130.1
129.9
129.8
129.7
129.6
Outer sphere turns cw
130.1
130.2
130.3
130.4
130.5
Outer sphere turns ccw
1X
10
Check the fan, the display and the follow-up.
DO NOT PERFORM DURING HEATING STAGE!
The current course is displayed on the connected
course receivers.
Switch B 37 (DIP switch)
1 2 3 4 5 6 7 8
OPEN
B39
1X
NOTE: If this function is activated during
the heating stage inadvertently,
the compass must switched
OFF and --ON again.