Compass
STD 22
Installation and Service manual
Compass STD 22
Compass STD 22 Compact
189
Edition: Feb. 17, 2006
3646/110--233.DOC010302
Following error groups can be displayed:
PCbP
= Error on Power Supply PCB
PCbS
= Error on sensor PCB
PCbC = Error on connection PCB
PCbG = Error on outer sphere PCB
Following error codes are possible (refering to their error group):
Error--
log
Comment
Error
group
E.L.01
Serial connection of Sensor PCB to Power Supply PCB
faulty
PCbP
E.L.02
Inductive transmission faulty
PCbP
E.L.03
System voltage (B5.5
⇒
B5.8) on Power Supply PCB
faulty
PCbP
E.L.04
Encoder voltage faulty
PCbP
E.L.05
System voltage (B5.1
⇒
B5.4) on Power Supply PCB
faulty
PCbP
E.L.06
Encoder faulty
PCbS
E.L.07
CAN dialogue from outer sphere PCB to sensor PCB
faulty
PCbS
E.L.08
Follow-up system faulty
PCbS
E.L.09
CAN1 and CAN2 operating voltage faulty
PCbC
E.L.10
Supporting liquid error
PCbG
E.L.11
System voltage (B21.5
⇒
B21.8) on sensor PCB faulty
PCbG
E.L.12
Operating voltage 24V faulty
PCbG
E.L.13
Operating voltage 15V faulty
PCbG
E.L.14
Heating operating voltage (B21.1
⇒
B21.4) faulty
PCbG
E.L.15
Operating voltage 72V faulty
PCbG
E.L.16
Operating voltage 78V faulty for 400 Hz
PCbG
E.L.17
Gyro supply 55V
eff
faulty
PCbG
E.L.18
Gyro current faulty
PCbG
E.L.19
Pump voltage faulty
PCbG
E.L.20
Pump current faulty
PCbG
E.L.21
Temperature sensor faulty
PCbG
E.L.22
Serial interface MC1 to MC2 faulty
PCbG
E.L.23
CAN interface from outer sphere PCB to sensor PCB
faulty
PCbG
E.L.24
Heating system faulty
PCbG
To delete the content of the error log book, see section 5.1.4 Nr. 14