Basic Steps

(Quick Installation Guide Pg. 1-20)

STEP 1: Safety Information (Pg. 2)
STEP 2: Wiring Installation (Pg. 6)

For PoE, use standard CAT 5 or better for both power and data. For all 8 sized 
products, check the PoE detection resistance of the illuminator is compatible with 
your PoE equipment (24.9KΩ class 6 is factory default). 

For low voltage (non-PoE) apply 24V DC to red and black cores of auxiliary cable 
and use standard CAT 5 or better for data connection. Connect external inputs 
and external output wires as required.

IMPORTANT: 

Ensure PoE equipment or 24V PSU are suitably rated
For 8 sized products check PoE detection resistance is set 
correctly
Ensure Cat 5 cable and auxiliary cable are correctly terminated 
and waterproofed after installation
If using low voltage, a CAT 5 cable must still be connected to 
the network for communication
If not using auxiliary cable, it must still be suitably terminated 
and waterproofed

STEP 3: Physical Installation (Pg. 9-10)

Adjust interchangeable lens if required. 
Fix to wall, pole or camera unit using U bracket provided or other Raytec bracketry.

IMPORTANT:

Ensure illuminator is rated to provide required viewing distances 
and select correct angle
Ensure illuminator is orientated in the correct direction

Summary of Contents for VARIO2 series

Page 1: ...Waterproof RJ45 connector Accessories optional 80 x 30 beam angle IHD 120 x 50 beam angle IHD System requirements A PC running Windows with network access running a modern web browser Full detailed in...

Page 2: ...diation emitted from this product May be harmful to eyes do not stare at the lamp For VAR2 IPPOE w4 1 VAR2 IPPOE w8 1 and VAR2 IPPOE w4 2 variants hazard distance is 1500mm For VAR2 IPPOE w4 3 VAR2 IP...

Page 3: ...e for Data and Optional PoE Photocell The illuminator has a photocell for automatic day night switching and has an External Input to act as a telemetry trigger input volt free or TTL and an External O...

Page 4: ...external output wires as required IMPORTANT Ensure PoE equipment or 24V PSU are suitably rated For 8 sized products check PoE detection resistance is set correctly Ensure Cat 5 cable and auxiliary ca...

Page 5: ...We recommend Raytec DiscoMan Tool as the easiest way to establish communication If using IP address for direct communication illuminator and computer must be in same network range STEP 5 Illuminator...

Page 6: ...oE device as follows The Factory Software version of the illuminator is shown by characters 4 5 6 in the product serial number The CAT5 cable is both the power and data connection for the illuminator...

Page 7: ...ce Selection Switch There is a 3 way switch on the VAR2 IPPoE w8 1 i8 1 and i8 1 C illuminators which can be used to change the PoE detection resistance and the PD class of the illuminator 24 9K and P...

Page 8: ...Central 24 9K 4 Compatible with legacy single signature high power PSE using class 4 power negotiation Right 12 5 K 4 Compatible with Phihong non standard high power PSE For further information regard...

Page 9: ...m of the product and remove the existing lens and then re attach the baseplate securely With no lens insert the product produces a 10o beam angle To alter to any other angle remove the existing lens a...

Page 10: ...fitted to unit Use for alternative power 24V DC if required Use for connecting external input and external output as required To maintain the IP rating of the product any cable not in use must be wat...

Page 11: ...OPTION 1 Raytec DiscoMan Tool We recommend the easiest and fastest way to identify and connect to illuminators is using the Raytec DiscoMan Tool where the IP address can be altered DHCP enabled as sta...

Page 12: ...pability Note If assigning the IP address fails check that there is no firewall blocking the operation and that the computer and illuminator have IP addresses in the same range Raytec DiscoMan Tool Ba...

Page 13: ...ng name software version model and the time the illuminator has been powered Hierarchy of Photocell vs Telemetry If the telemetry function is enabled then the photocell must detect that it is dark for...

Page 14: ...al or VMS Local To operate the illuminator via a VMS or third party application that uses the Raytec API then the illuminator mode should be set to VMS or VMS Local In VMS mode the illuminator will ig...

Page 15: ...dard Setup Factory Defaults The illuminator is operating in Local mode and will respond only to its own photocell and telemetry status By default the illuminator is NOT assigned to a group The illumin...

Page 16: ...Photocell Only Active State Short Circuit Low External Input Type of Input Volt Free Active State Short Circuit Low Photocell Photocell Sensitivity 20 lux Basic Web Page Functionality All web pages h...

Page 17: ...by VMS or HTTP commands Adv Settings Allows for further detailed setup of External Input External Output Photocell sensitivity level and duration of Override Access Change passwords Network Allocate I...

Page 18: ...of our model names the size of the illuminator details box to the right has been increased If you have previously used a Vario IP PoE on your machine your browser will have remembered the old style a...

Page 19: ...VARIO2 IPPOE unit see page 7 for required ratings Check connection and wiring of CAT5 6 cable to VARIO2 IPPOE Verify link has been established with the router switch to which the illuminator is conne...

Page 20: ...teccctv com Raytec Ltd Unit 15 Wansbeck Business Park Rotary Parkway Ashington Northumberland NE63 8QW United Kingdom Raytec Americas Tel 1 613 270 9990 ussales rayteccctv com Raytec Systems Inc 800 3...

Reviews: