14
rayteccctv.com
Raytec Global Tel: +44 (0) 1670 520055
Americas Tel: +1 613 270 9990
Users & Passwords
Name
Password
Operator
user
password
Administrator
admin
password
Log-in, Security & Basic Illuminator Setup
Log-in using Operator or Administrator user names and passwords. Operator has
limited access rights. Administrator has full access rights.
Defaults (User Names & Passwords are case sensitive):
In order to maintain maximum security of your system, we recommend you change
both passwords at the earliest opportunity (for further information, please see full
installation instructions, available from the Raytec website).
Software version 2.5.x or above: When you log in with the default credentials for
the administrator for the first time you will be forced to change the password.
Take instant control of an illuminator by pressing the Override button on the home
page. This will countdown for 30 minutes to allow the user to control the illuminator
and then will revert to standard settings automatically or if the Override button is
deselected. Override is only available when the illuminator mode is set to
Local,
HTTP + Local
or
VMS + Local
.
To operate the illuminator via a VMS or third party application that uses the Raytec
API, then the illuminator mode should be set to
VMS
or
VMS + Local
. In VMS mode
the illuminator will ignore Photocell and External Input triggers and respond only to
valid VMS commands. In
VMS + Local
mode the illuminators can be controlled via
a VMS system whilst also still responding to local photocell and telemetry triggers.
To operate the illuminator with an application that uses the HTTP API, then the
illuminator mode should be set to
HTTP
or
HTTP + Local
. In HTTP mode the
illuminator will ignore Photocell and External Input triggers and respond only to valid
HTTP commands. In HTTP + Local mode the illuminators can be controlled with
HTTP commands whilst also still responding to local photocell and telemetry triggers.
VMS integration allows the illuminator(s) to be directly controlled and triggered
by events within the VMS environment such as scheduled events, alarm triggers,
camera commands, etc.
HTTP Integration allows the illuminator to be directly controlled and triggered on
receipt of valid HTTP commands generated on the network from VMS, cameras or
other components capable of generating HTTP commands.
The illuminator mode can be changed on the Settings / Groups page. The default
illuminator mode is
Local
.