The next step in the commissioning process requires the adjustment of some key settings. To
achieve this you will need to enter one of the four calibration modes, Dealer Calibration.
Enter Dealer Calibration mode
As improper use of the Dealer Calibration settings can seriously impair SmartPilot
performance, we have made entry to the Dealer Calibration mode more difficult. Ensure you
follow the instructions in this step carefully.
1. Start with the SmartPilot in STANDBY mode.
2. Enter DEALER CAL as follows:
• press and hold the
standby
key for two seconds to enter the Calibration mode
• when the screen shows DISPLAY CAL, press the
disp
key until you see the DEALER
CAL screen
• press the
auto
key: the display will change to CAL ?
• press
-1
and
+1
keys together to enter Dealer Calibration mode
Set the vessel type to STERN DRV
When you select a vessel type, the SmartPilot automatically selects appropriate default values
for various other calibration settings.
Some of these settings will be checked later in this procedure and the remainder should not
require any adjustment.
Use this calibration setting to select Vessel Type STERN DRV for Mercury Verado outboards:
1. Use the
disp
key to scroll through the Dealer Calibration pages until the display shows
either DISPLACE, SEMI DIPLACE, PLANING,STERN DRV, WORK BOAT, SAIL BOAT.
2. Use the
-1
or
+1
keys to select
STERN DRV
.
3. Press
disp
to select the new type of boat and move to the next calibration option.
At the CAL ? screen, press +
together to enter DEALER CAL
2 sec
x3
C A L ?
-1
+1
Dealer calibration mode
D8559-1
Summary of Contents for Verado
Page 8: ...vi SmartPilot Verado Installation and Commissioning Guide ...
Page 10: ...viii SmartPilot Verado Installation and Commissioning Guide ...
Page 24: ...14 SmartPilot Verado Installation and Commissioning Guide This page is intentionally blank ...
Page 66: ...56 SmartPilot Verado Installation and Commissioning Guide ...