6.1 Warnings and cautions
Important:
Before proceeding, ensure that you have read and understood the
warnings and cautions provided in the following section of this document:
6.2 Wind transducer location requirements
When selecting a location for your wind transducer, it is important to consider
a number of factors.
• It is recommended the transducer is installed facing forwards.
• The mounting surface must be horizontal. If the surface is not horizontal,
use the mast manufacturer’s accessory or a suitable shim to create a
horizontal surface.
• The transducer should be mounted as high as possible and away from
any equipment which may shield the transducer or otherwise disturb the
air flow to the transducer.
• It should be far enough away from equipment or cabling that may cause
interference, such as masthead lights or Radar cabling.
• There must be a viable route for the transducer’s cable to be routed to
the supplied gateway.
• The vane and cups must be able to spin freely.
• There is sufficient access for installation and servicing.
6.3 Gateway location requirements
The gateway can either be mounted on a flat surface using fixings, or secured
in a suitable location using cable ties. When selecting a location for the
gateway, it is important to consider a number of factors.
•
Potential ignition source
— This product is NOT approved for use in
hazardous/flammable atmospheres (such as in an engine room or near
fuel tanks).
•
Ventilation
— The product should have adequate airflow around it, at all
times.
•
Damage
— Install the product in a location where it will be protected from
physical damage and vibration.
•
Mounting surface
— Ensure the product is adequately supported on a
secure surface. Do not mount the product or cut holes in places which may
damage the structure of the vessel.
•
Cabling
— Ensure the product is mounted in a location which allows the
proper routing, support and connection of all cables:
– Minimum bend radius of 100 mm (3.94 in), unless otherwise stated.
– Use cable clips at regular intervals to prevent stress on connectors.
– If your installation requires multiple ferrites to be added to a cable,
additional cable clips should be used to ensure that the extra weight
of the cable is supported.
•
Water ingress
— The product is designed to be installed below decks in
a protected area away from prolonged and direct exposure to rain and
salt spray. To prevent water ingress, the product’s cover must be fitted in
all installations.
•
Electrical interference
— Select a location that is far enough away from
equipment or cabling that may cause interference, such as motors,
generators, radio transmitters or receivers, magnetic compass or power
cables.
•
Network connection
— Select a location that is as close as possible to
a spur connection on the vessel’s SeaTalkng ® / NMEA 2000 network
cabling. This will help to keep cable runs to a minimum.
21
Summary of Contents for RSW-Wired
Page 2: ......
Page 4: ......
Page 16: ...CHAPTER 4 PARTS SUPPLIED CHAPTER CONTENTS 4 1 Parts supplied page 17 16...
Page 36: ...CHAPTER 10 GROUND CONNECTION CHAPTER CONTENTS 10 1 Gateway ground connection page 37 36...
Page 45: ...CHAPTER 13 MAINTENANCE CHAPTER CONTENTS 13 1 Service and maintenance page 46 Maintenance 45...
Page 68: ......
Page 71: ...WEEE Directive 8 What s in the box 17 Wind transducer Configuration 42 44 Wire stripping 39...
Page 72: ......
Page 73: ......