3460 Fast’R
C-2
Operating Modes
Data Operation
Full-duplex, point-to-point.
Accessway enclosure-card modems and stand-alone units are fully
interoperable.
Modulation Modes
ITU-T V.17
ITU-T V.27ter
ITU-T V.29
ITU-T V.21
Environmental Limits
Operating Conditions
Condition
Modem Card
AccessWay
Stand-Alone
Temperature
Operating temperature: 32
°
to 122
°
F (0
°
to 50
°
C)
maximum
Relative Humidity
5% to 90% (noncondensing)
Vibration and Shock
In approved shipping container, conforms to the
National Safe Transit Association Percipient Test
Specification requirements.
The stand-alone modem requires locking clips for stacking units to a
maximum recommended height of 9 units.
Non-Operating Conditions
Condition
Modem Card
AccessWay
Stand-
Alone
Temperature
-40
°
to +158
°
F (-40
°
to +70
°
C)
Relative Humidity
5% to 90% (noncondensing)
Vibration and Shock
In approved shipping container, conforms to the
National Safe Transit Association Percipient Test
Specification requirements.