Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-C4000XZ~12000XZ
31
5.5 Programming Mode
In “ON” mode, when the current program number of the laser is not 0, the laser runs in the
“Programming” mode. Please use the Raycus Host Computer Software to edit the waveform and
select the pre-run program number.
When the laser is in the internal control mode:
Send the “EMON” command or press the
“ON”
button, the laser will start to run the program,
Send the “EMOFF” command or press the
“OFF”
button can terminate the laser emission at any time
When the laser is in the external control mode, the rising edge of MOD starts to operate
theprogram, and the falling edge of MOD can terminate the program at any time.
5.6 REM Mode
3.3.8 AD enable mode
When both A1 and A6 of XP1 are set high, the laser operates in AD mode, and the current
laserpower is determined by the analog voltage of pin 1 and pin 2 of xp4; When A6 of xP1 is set low
orsuspended, the current laser power is set by sending "SDC XX" command through PC software
orcommunication.
3.3.9 Emission external control
When both A1 and A3 of XP1 are set high, the laser is in the internal control mode, and the laser
emission is controlled by the computer software's light on button or through communication
sending"EMON" to control the light output, and "EMOFF" to control the light off; When A1 of XP1
is sethigh, A3 is suspended or set low, the laser is in the external control mode, the output light
isdetermined by the high and low TTLofthe MOD signals at A2 (XP1) andpin 1/2 (XP2).
3.3.10 Red light control
When both A1 and A3 of XP1 are set high, the laser is in the red light internal control mode,
andthe red light is controlled by the computer software red light button or through communication by