Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-C4000XZ~12000XZ
12
Figure 11 Output optical cable with white dust cover removed
3) Use a cotton swab and anhydrous ethanol to clean the metal casing of the optical cable, then
remove the end cap (with window) attached to the optical cable, and place it on a clean paper .
Figure 12 Remove the A -type end cap on the optical cable
4) Check the cleanliness of the end caps in this state. If the cleanliness is not enough, please clean
the end caps. Please refer to the cleaning method: http://www.raycuslaser.com/view/1852.html ,
video reference: https://mp. weixin.qq.com/s/hRXrPkb8DAyvDYegSWwYLg .
Note 1: The end cap cleaning is generally performed by our professional staff. If the
customer needs to operate it by himself, we need to go through the relevant training of our
staff and obtain the relevant qualifications before the above operations can be carried out.
If the operation method is improper, it will cause irreversible and serious damage to the
output optical cable during use.
Note 2: The connection with the cutting head (or welding head) still needs to be carried
out in a clean workbench, and it is necessary to check the cleanliness and smoothness of
the relevant components of the cutting head (or welding head) itself.
3.4 Cooling Requirements
Table 4 Cooling Requirements
Model
C4000XZ
C6000XZ
C8000XZ
C10000XZ
C12000XZ
Cooling capacity (kW)
≥8
≥12
≥16
≥20
≥24
Minimum flow (L/min)
)
>
35
>
52
>
64
>
79
>
94
Input pressure (Bar)
4~6
Hose inner diameter
(mm)
Φ25
Φ32
Cooling water
temperature (
℃
)
24±1