Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-C15000TZ
70
Table 17 command meaning in laser working status
Code (1 Byte)
Parameter1(2 bytes
)
Parameter 2
(
4 bytes
)
Note
1
Stop
none
none
The program end
command. the last
command must be this
command.
2
SPT
0
~
65000
(
ms
)
0
~
65000(W)
Change power to 2 in
time 1
3
SPR
0
~
65000
(
W/ms
)
0
~
65000(W)
Change power to 2 in
power change ratio 1
4
WAIT
1
Wait for sync
signal low level
Null
2
Wait for sync
signal high level
Null
3
Wait for sync
signal rising
Null
4
Wait for sync
signal dropping
Null
5
Wait
0
~
65000ms(int)
5
GOTO
0
~
99
line
-1
Switch at low sync
signal
Jump to different line
when comply
0
~
99
line
-2
Switch at high
sync signal
Jump to different line
when comply
0
~
99
line
0
~
1000000
Times of jump to
subject line
Times of loop jump to
subject line
6
OUT
1
SO
1
sync signal low
level output
2
sync signal high
level output
7
EXT
Power
1
0
~
10V