Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-C15000TZ
31
d)Close the rear panel circuit breaker, release the laser front panel emergency stop switch; turn on
the key switch ,and the laser has a temperature and humidity alarm,turn off the key switch.
After the air conditioner works for 10minutes,turn on the key switch again.Wait for the air
conditioner to continue working for 10minutes until the temperature and humidity alarm of the
laser does not appear,at this time,turn off the key switch and turn on the water cooler;ensure
that all laser doors are closed, optical cable output head has been inserted into the cutting head
(or corresponding equipment), all interlock interfaces have been closed;
e) Select the required control mode according to 1.4 control mode, turn on the key switch, start the
main power supply waiting for the laser to Ready, the laser Ready, the tricolor green light
above the machine, representing that the laser can light.
5.Control Mode Selection
The Raycus high-power CW laser has two control modes: namely ON mode and REM mode.
Users can select the mode to be entered through the key on the front panel.
Table 11 ON mode and REM mode functions.
ON
Mode
AD Mode
External
control
programming
mode
Power
Laser ON and off
Red laser
close
①
close
②
-
communication
⒀
communication
⑾
communication
⑿
Enable
③
close
②
-
XP4-1/2 pin
pressure
communication
⑾
communication
⑿
close
①
Enable
④
-
communication
⒀
XP2-1/2 pin level
communication
⑿
Enable
③
Enable
④
-
XP4-1/2 pin
pressure
XP2-1/2 pin level
communication
⑿
REM
Mode
close
⑤
close
⑥
close
⑦
communication
⒀
communication
⑾
communication
⑿
Enable
⑧
close
⑥
close
⑦
XP4-1/2 pin
pressure
communication
⑾
XP1-A1/A5 is
high level
close
⑤
Enable
⑨
close
⑦
communication
⒀
XP1-A1 laser request is
high
XP1-A2 laser emission
enable is high
XP2-1/2 input MOD
singal
XP1-A1/A5 is
high level