Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-C3000XZ~RFL-C12000XZ
18
ALARM Indicator
:
INTERLOCK alarm indicator. This indictor will illuminate Yellow during the control board powering-
on and self-check processes. When the self-check is done and all INTERLOCK ports are working properly
this indicator will turn off. When the laser source is in work, any INTERLOCK malfunction will bring this
indicator to illuminate again.
STOP Button
:
Press down to turn the laser off immediately in emergent situations. Turn it clockwise to release the
button (recover to the normal position). Then use the key to turn the laser back on after the emergency is
lifted.
Status Lamp
:
When the laser key switch hits “ON” or “REM”, the green light is on. The red indicator is on when
the laser is emitting. When the fault occurs, the yellow indicator light is on, accompanied by a siren sound.
(Note: some certain client-customized version of XZ series product may have different definitions for each
colored indicator of the status lamp).
4.2
Rear Panel
Figure 9 shows the rear panel of the product
:
AC Input
:
The socket for mains in. Please use only the enclosed power cord provided by Raycus. The socket
features a protective cover and a lock. Please use the protective cover and lock when not using the product.
INTERFACES
:
Control interface panel, including HARDWIRING XP1, SAFETY XP2, RS232, ANALOG XP4,
ETHERNET XP5 interfaces. This control panel provides all control input signals and feedback output
signals, including: RS232 communication, network port communication, laser on/off control, laser remote
control mode selection, analog control, modulation signal, Interlock interface, laser emission power
feedback signal, etc., Refer to Table 5, Table 6, Table 7, Table 8 and Table 9 for control line definitions.
This socket comes with a protective cover and the lock. When users are not using the product, users shall
cover the power input socket with the protective cover and lock it with the lock.
WATER
:
Pagoda type water tube connector. The inlet and outlet are used for inflow and outflow of cooling
water.The rear views of other higher power models are shown below for reference.
, the circuit breaker (air switch) on the rear panel of the laser is the total power
switch of the laser.