Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-C3000XZ~RFL-C12000XZ
12
Figure 4 External dimensions of the RFL-HQBH fiber delivery cable connector
b)
RFL-6000/6000-ABP uses the RFL-QD model cable connector, and the external dimensions of the
output optical cable connector are shown in Figure 5:
Figure 5 External dimensions of the RFL-QD fiber delivery cable connector
NOTE:
a)
The dimensions in the above figures are in the unit of mini-meter (mm).
b)
Before the laser is powered on, make sure that the two copper contacts (interlock pins) on the fiber
connector are shorted well, otherwise the laser will not work properly.
c)
Before installing the fiber delivery cable connector into the laser processing head, the lens of the
fiber delivery cable must be inspected carefully.
d)
If the fiber delivery cable lens is dirty, the lens must be cleaned well. It is forbidden to disassemble
the protective lens by anyone other than staff of Raycus or Raycus authorized personnel, otherwise
the warranty will be invalidated.
3.2
Installation Requirements
a)
Place the laser horizontally in a suitable position and fix it as necessary;
b)
Before the laser is powered on, check if the power supply has the correct voltage (AC 323V ~ 437V,
50/60Hz, see Table 2 Product Technical Data Sheet for details), and the grounding line (PE)shall be
well grounded all time during powering on;