69
i4507 Offshore Lattice Boom Crane
Instruction Manual
55M4507OBE00-B
The i4507 system can support up to
4
generic interfaces. Each one can support a
wind speed sensor, an inclination level sensor and an absolute rotation encoder .
Activation of every generic card is done in the
calibration menu
section ‘‘
Enable/
Disable I/O’
’.
D) Generic Interface Errors
Error Message
Execution Process
Cause of Error
Lost communication with
generic card X
The i4507 system does not
receive data from generic
interface. If “
time out
” delay is
reached, then a communication
error is displayed
1) The generic interface is
broken
2)
The cable that links the
interface to the canbus network
is defective
.
Cant X on generic X
Waiting for a valid value of the
Cant X from the interface
1) The X axis of the
inclinometer is not calibrated
2) A wire between the cable
that links the interface to the
canbus network is cut.
Cant Y on generic X
Waiting for a valid value of the
Cant Y from the interface
1) The generic interface is
broken.
2) A wire between the cable
that links the interface to the
canbus network is cut.
AIN 1 on generic X
Waiting for a valid value of the
AIN 1 input from the interface
1) The AIN 1 input of the
generic interface is not
calibrated
2) A wire is cut between the
sensor connected to AIN 1
input and the interface
AIN 2 on generic X
Waiting for a valid value of the
AIN 2 input from the interface
The AIN 2 input of the
generic interface is not
calibrated
2) A wire is cut between the
sensor connected to AIN 2
input and the interface
Absolute rotation encoder
Waiting for a valid signal from
the absolute interface
Absolute encoder is defective
.
Rotation encoder’s 0 ref
The proximity switch has been
detected when encoder did not
receive a pulse
Rotation encoder is defective
.
Generic Dr +
The
5
volts reference voltage
is
not
valid (if < 4.5 volts or >
5.5 volts)
.
The generic card is
defective
Summary of Contents for i4507
Page 2: ...This page has been intentionally left blank ...
Page 3: ...This page has been intentionally left blank ...
Page 4: ...This page has been intentionally left blank ...
Page 6: ...55M4507OBE00 B 6 i4507 Offshore Lattice Boom Crane Instruction Manual ...
Page 8: ...This page has been intentionally left blank ...
Page 12: ...This page has been intentionally left blank ...
Page 20: ...This page has been intentionally left blank ...
Page 30: ...This page has been intentionally left blank ...
Page 32: ...This page has been intentionally left blank ...
Page 76: ...55M4507OBE00 B 76 i4507 Offshore Lattice Boom Crane Instruction Manual Notes ...
Page 77: ...This page has been intentionally left blank ...
Page 78: ......