Error message
Execution process
Cause of error
External board
(Logger)
The
Logger
option must be
activated. Upon startup, the
system verifies that logger
card is present.
1) The Logger card is not
installed,
2) There is a problem
with one of the two flash
memories.
Low battery on
data logger
The System detected that the
Lithium battery is low. This
may cause clock to stop or
lose precision.
1) The Logger card’s plastic
cap must be replaced. It
contains the battery.
(See illustration below for
replacement).
No duty
The present crane configu-
ration is not valid.
1) Verify if the load chart
corresponds to the crane
to be calibrated.
2) Does load chart depend
on rotation?
3) Does load chart depend
on DIN inputs?
No Parameter
The Crane dimensions must
be entered in the system.
The Load value will be null
or wrong.
1)
CL3
,
CL4
and
CL7
values
should
Not
be at zero.
No 2nd duty found
The
Comparison angle/
radius
” option must be
activated. Thus a jib capacity
is evaluated by its angle
(offset) against the jib’s chart,
in comparison to the same
jib’s capacity evaluated by
its radius against the
Main
boom
chart. The smallest
will be selected.
1) The
Load chart
must be
programmed for this kind
of application. “
One
touch
” field is used in the
load chart for this option.
5.7.1
Internal Peripherals (cont’d)
58
Telescopic Cranes Pressure Sensing
Instruction Manual
i3500 Troubleshooting