During start up and other operation processes, the i3500 system analyses all
interactions between internal peripherals (memories, controllers, extension
cards, etc.) and also external ones (physical cards linked to the Canbus network)
If you have any questions or need technical assistance, please contact our
Technical Service Department at
RaycoWylie
.
5.7
Error Messages and the use of the key
5.7.1
Internal Peripherals
Error message
Execution process
Cause of error
Data logger:
Test failed
Upon startup, the system
verifies if the Logger Card
option is activated.
1) The Logger card is not
installed.
2) The connector has de-
fective soldering
or is broken.
3) There is a problem
with the logger card
Rld flash:
Test failed
When starting system, there
is a verification (writing/
reading) of the flash chip of
the limit programmed (range
limiting device).
1) There is a problem with
flash memory (
U52
)
Chart:
Test failed
Upon startup, the system
does a read verification of
the load chart flash memory
chip.
1) The Load chart chip is not
installed.
2) Verify the kind of mem-
ory it must be a flash
memory.
3) There is a problem with
flash memory (
U12
).
Memory bank ‘‘C”:
Test failed
Upon startup, the system
does a read/write verification
of bank C EEPROM chip.
It is to save the system’s
operation parameters. Ex.
winch, number of falls or
parts of line, duty #
1) There is a problem with
EEPROM
memory
(
U45
)
56
Telescopic Cranes Pressure Sensing
Instruction Manual
i3500 Troubleshooting