55M3500MNE rev. E
Telescopic cranes with derrick pressure sensors Calibration Manual i3500
27
2.2.4 Digital inputs configuration: ("- dig. inputs config.")
Digital inputs can be configured for different input types, or for their functionality as
defined in
Table 1.
The Interlock inputs are used to detect if a boom section is locked in place with a pin. It
can be detected using a magnetic or mechanical proximity switch.
The Din inputs are use to detect working area, i.e. over end, over side. It can be
detected using a magnetic or mechanical proximity switch.
The External Bypass is required for the EN13000 compliance. When this function is
used the “bypass” key on the i3500 display is disabled. Only an external spring key
switch can be used to bypass the system.
Some options are available for specific customer needs.
RaycoWylie Systems will determine which option should be selected in the installation
instruction.
TABLE 1: Digitals inputs configuration:
DIN 4
DIN 3
DIN 2
DIN 1
Option #1
Interlock #1
Din #3
Din #2
Din #1
Option #2
Interlock #1
Interlock #1
Din #2
Din #1
Option #3
External
Bypass
Interlock #2
Interlock #1
Din #1
Option #4
Optional #3
Optional #2
Optional #1
Bypass
External