![background image](http://html.mh-extra.com/html/raven/scs-660/scs-660_programming_788843002.webp)
2 © 2010 Newton Crouch Inc. This information is the property of Newton Crouch Inc. and is loaned confidentially for the sole use of our customer. It must not be
used in any way detrimental to our interest or shared with outside parties. Technical Tips/Raven—SCS 660 Programming Instructions revised
Rev 2.27.18
Your console must be calibrated with constants & selections before using. Mark your correct
information here and have this sheet with you as you program your console. The most com-
monly used constants are indicated by
Constants1—4: move through the constants using the CE key, lock in your selection by using
ENTER key
Start at
Area:
__________
1
US (Volume per Acre) ...
SI (Volume per Hectare)
TU (Volume per 1000 Sq Ft) for turf primarily
Sensor:
__________
2
SP 1—Wheel drive
SP 2—Radar...
Programming for your Raven SCS 660 Console Granular Mode
Console calibration is a one-time procedure that, once it has been performed, does not have
to be repeated. Turning the POWER ON/OFF switch does not affect the console’s memory—
all data is retained
.
(speed from satellite)
CALIBRATION KEYS - - Used to enter data into the Console to calibrate the system
BOOM CAL
Length of Boom. Select Boom number by using the UP/DOWN arrow keys
SPEED CAL
Determined by Speed Sensor
METER CAL
Meter Calibration Number—Has 2 settings for Dry
1. Spreader Constant—Gate Height Factor
2. Product Density
VALVE CAL
Valve Response Time
RATE 1 CAL
Target Application Rate
RATE 2 CAL
Target Application Rate
TIME
24 Hour Clock (military time)