28
of "on" means alarm is enabled; a value of "oFF" means alarm is disabled.
c)
Depress
to advance to DATA LOGGER TRIGGER VALUE.
DATA LOGGER TRIGGER VALUE
a)
GRAN display will show "SPr". LIQ display will show "triG". DATA display
will show "0".
b)
Enter the TRIGGER VALUE.
c)
Depress
to advance to DATA LOGGER TRIGGER UNITS.
IMPORTANT: The TRIGGER VALUE default value is "0". This value must be changed
to a desired number ranging from 1-9999. The DATA LOGGER features will
not work if this number is "0".
DATA LOGGER TRIGGER UNITS
a)
GRAN display will show "SPr". LIQ display will show "Unit". DATA display
will show "Ft"["MEtr"].
b)
Depressing
steps the DATA display between "Ft"["MEtr"] and "SEC".
A value of "Ft"["MEtr"] means feet [meters], or a value of "SEC" means
seconds have been chosen as the unit of measurement for the TRIGGER VALUE
programmed previously.
c)
Depress
to advance to DATA LOGGER.
DATA LOGGER ON/OFF
a)
The DATA LOGGER uses the communications strings listed in Appendix 12 to
pass data out through the serial port. The data is sent at a set time
interval or a set distance traveled, as determined by the values entered
in the DATA LOGGER TRIGGER VALUE and DATA LOGGER TRIGGER UNITS. Upon each
trigger, the Actual Rate string, Data Strings 1, 2, 3, 4, and 5, and the
Time/date string are sent, in that order. When a Console calibration value
is changed, the Console will automatically send out the Cal 1, 2, 3, 4,
and 5 strings. When a Console switch is changed, the Data 1, 2, 3, 4, 5,
Time/Date, and Cal 1, 2, 3, 4, 5 strings will be sent by the Console. The
Data, (with Time/Date string included) and Cal strings can also be
requested by the data logger using the request strings shown in Appendix
12.
b)
GRAN display will show "SPr". LIQ display will show "dLoG". DATA display
will show "oFF".
c)
Depressing
steps the DATA display between "oFF" and "on". A value
of "oFF" means DATA LOGGER is disabled; a value of "on" means DATA LOGGER
is enabled.
Summary of Contents for DCS 700
Page 1: ...DCS 700 INSTALLATION AND SERVICE MANUAL ...
Page 3: ......
Page 4: ...Manual Rev B DCS 700 063 0171 711 7 99 016 0159 775 ...
Page 61: ...NOTES ...