Spreading operation with the QUANTRON-A control unit
5
90
5.3
Spreading with automatic operating mode (AUTO km/h + AUTO kg)
Mass flow control with the M EMC function
Mass flow is measured separately on both spreading disc sides. Thus deviations
to the specified application rate can be immediately corrected.
The M EMC function requires the following machine data for mass flow control:
PTO speed
Spreading disc type
A PTO speed between 450 and 650 rpm is possible.
The desired speed should remain constant during spreading (+/- 10 rpm)
.
High control quality can therefore be ensured.
The idle measurement is
only
possible if the actual PTO speed deviates by
max. +/- 10 rpm
from the entry in the
PTO
menu. Outside of this range, idle
measurement is not possible.
Precondition for spreading:
The
AUTO km/h + AUTO kg
operating mode is active (refer to
).
1.
Fill the hopper with fertiliser.
2.
Adjust fertiliser settings:
Application rate (kg/ha)
Working width (m)
3.
Enter the PTO speed in the corresponding menu.
See also “PTO shaft“ on page -49
.
4.
Select the spreading disc type used in the corresponding menu.
See also “Spreading disc type“ on page -49
5.
Switch on PTO shaft.
6.
Set PTO shaft to the PTO speed entered.
The
Idle measurement
screen is displayed.
Figure 5.3:
Idle measurement information screen
7.
Wait until the progress bar has entirely passed through.
Idle measurement is finished.
Idle time is reset to 20 min.
Idle measurement
Idle measurement
required!
Set spreading speed,
maintain constant.
Set spreading speed
Current joint shaft speed
Summary of Contents for QUANTRON-A AXIS-M 20 Q
Page 6: ...Table of Contents IV...
Page 10: ...User instructions 1 4...
Page 16: ...Layout and function 2 10 Figure 2 5 Control unit display example MDS operating screen 3 11...
Page 24: ...Layout and function 2 18...
Page 92: ...Operation QUANTRON A 4 86...
Page 104: ...Spreading operation with the QUANTRON A control unit 5 98...
Page 114: ...Index D...
Page 116: ......