Spreading operation with the QUANTRON-A control unit
89
5
5.2.2
Spreading operation with one section and in boundary spreading mode
During the spreading operation, the sections can be changed gradually and the
limited border spreading can be activated. The figure below shows the operating
screen with activated limited border spreading and activated sections.
Figure 5.2:
Operating screen, one section on the left, limited border spreading
side on the right
[1] Quantity change in boundary spreading mode
[2] Spreading side on the right in the boundary spreading mode
[3] Right spreading side is activated
[4] Reduce or increase left section
[5] Left section adjustable in 2 steps (VariSpread 4)
The spreading quantity on the left is set to the full working width.
The
Right limited border spreading
function key has been pressed, limited
border spreading is active and the spreading quantity is reduced by 20 %.
Press the
Reduce left spreading width
function key in order to reduce the
section by one step.
By pressing the
C/100%
key, full working width is reapplied immediately.
For TELIMAT versions without sensor only: By pressing the T key, the limited
border spreading is deactivated.
3
5
1
2
4
Summary of Contents for QUANTRON-A AXIS-M 20 Q