Operation QUANTRON-A
47
4
Selecting the section:
5.
Set the spreader side on which the calibration is to be carried out.
Press the
F1
function key to select
left
spreading side.
Press the
F4
function key to select
right
spreading side.
The symbol indicating the selected spreader side has a red background.
Running the calibration test:
6.
Press the
Start/Stop
key.
The metering slider of the previously selected section opens and the cali-
bration is started.
The
Run calibration
operating screen is displayed.
7.
Press the
Start/Stop
key once more.
The calibration is completed.
The metering slider closes.
The display shows the
Input collected weight
menu.
n
WARNING
Risk of injury during calibration
Rotating machine components and ejected fertiliser may cause
injury.
Before starting
the calibration, ensure that all precondi-
tions have been met.
Follow the
Calibration
chapter in the machine’s operating
manual.
NOTICE
The calibration can be stopped at any time by pressing the
ESC key
. The me-
tering slide is closed and the
Fertiliser settings
menu is displayed.
NOTICE
The calibration time is not relevant for the accuracy of the results. However,
a
minimum of 20 kg
should be calibrated.
Summary of Contents for QUANTRON-A AXIS-M 20 Q
Page 6: ...Table of Contents IV...
Page 10: ...User instructions 1 4...
Page 16: ...Layout and function 2 10 Figure 2 5 Control unit display example MDS operating screen 3 11...
Page 24: ...Layout and function 2 18...
Page 92: ...Operation QUANTRON A 4 86...
Page 104: ...Spreading operation with the QUANTRON A control unit 5 98...
Page 114: ...Index D...
Page 116: ......